| Exam ID: 78 or Level 78 |
| |
- 70 multiple-choice questions
- 3½-hour limit
- Open book
|
| Sample Examination Questions: The
sample questions are provided to give you an idea of the
style and format of examination questions. The questions
are not intended to represent content, references or questions
that will be on the examination. They are not intended
nor should they be referenced/used as a study tool for
the examination. |
| 1. |
Fenestration includes all of the following,
except _____. Click for Answer
|
| |
|
A. |
glass block |
| |
|
B. |
curtain wall |
| |
|
C. |
air intake louvers |
| |
|
D. |
rollup warehouse doors |
| 2. |
A retail store with 12 foot walls is 100
feet wide by 50 feet deep. The street side has three 28'
by 8' widows, and two 6" by 6'-8" glass doors.
The other wall do not have any glazed fenestration. The
roof has twenty 4' by 4' skylights.
Is this project eligible to use the prescriptive compliance
option? Click
for Answer |
| |
|
A. |
Yes |
| |
|
B. |
No, the skylight area is too large. |
| |
|
C. |
No, the vertical fenestration is too large. |
| |
|
D. |
No, both the vertical fenestration and
the skylight areas are too large. |
| 3. |
An office space has the following lighting:
12 fixtures with two 32-watt T-8 lamps and electronic
ballasts rated by the manufacturer at 60 watts per fixture.
2 fixtures with 60 watt incandescent lamps screwed into
fixtures with a maximum labeled wattage of 150 watts each.
2 fixtures with 13 watt compact fluorescent lamps in a
pin base attached to an 8 foot section of track lighting.
What is the connected lighting power for compliance purposes?
Click
for Answer |
| |
|
A. |
914 watts |
| |
|
B. |
1046 watts |
| |
|
C. |
1094 watts |
| |
|
D. |
1260 watts |
| 4. |
For a project in King County, Washington,
the equipment schedule on the design drawings show two
rooftop single-package air-source heat pumps with electric
resistance space heat.
One is a 5-ton unit with a 9.9 SEER. The other unit is
a 10-ton unit with a 10.0 EER. Neither unit has an economizer.

Do the heat pumps comply with the code?
Click
for Answer |
| |
|
A. |
Yes |
| |
|
B. |
No, the SEER for the 5-ton unit is too low
and the 10-ton unit is required to have an economizer. |
| |
|
C. |
No, the EER for the 10-ton unit is too low
and the 10-ton unit is required to have an economizer. |
| |
|
D. |
No, the EER for the 10-ton unit is too
low and both units are required to have economizers.
|
|
|
|
|
Return to certification category
|