Sample Examination Questions: The sample questions are provided to give you an idea of the style and format of examination questions. The questions are not intended to represent content, references or questions that will be on the examination. They are not intended nor should they be referenced/used as a study tool for the examination.
1. Given: A home will be constructed in Armstrong County, Texas.
The required insulation R-value in the ceiling of the home using the prescriptive component method is _____. Click for Answer
    A. 13
    B. 19
    C. 30
    D. 38
2. A glazed block opening in an exterior wall has a default fenestration U-factor of ____. Click for Answer
    A. 0.55
    B. 0.60
    C. 0.65
    D. 0.85
3. Given: A home will be constructed in Armstrong County, Texas.
The windows are double pane with metal frames that include a thermal break. The number and sizes of windows are - four 6' ×4', two 2' × 3', and one 8' × 5'. The manufacturer states the U-factor for the 6' × 4' windows is 0.35 and the U-factor for the 2' × 3' is 0.30. The 8' × 5' window is not labeled. Does the combination of these windows meet code using the component method?
Click for Answer
    A. Yes.
    B. No, the U-factor for the small windows is too large.
    C. No, the manufacturer needs to change the U-factors for the smaller windows.
    D. No, the large window either needs to be replaced or the manufacturer needs to state the rated U-factor to determine compliance.
4. Which of the following work is not exempt from the Energy Code? Click for Answer
    A. Restoration of a historic building.
    B. Replacing the windows in a hospital.
    C. Converting a second floor of an office building into apartments.
    D. Installing storm windows over the existing windows of a condominium.
5. Which of the following elements does not have mandatory requirements in the code? Click for Answer
    A. A heat pump.
    B. Slab on grade floor.
    C. Air leakage from a sliding door.
    D. Dropped ceilings next to the thermal envelope.

Return to certification category


 

Contact Information

1-888-ICC-SAFE (422-7233), ext.
Certification Examinations
33806
Certification Renewal
33815
MCP Certification Examinations
33806
CBO Examinations
33806
Contractor Examinations
33805
Legacy Examinations
33823
UST/AST Examinations
33823
Special Inspection Examinations
33823



Click for more information

 

 
Home | Membership | ICC Store | Codes & Standards | Government Relations
Training | Certification & Testing | Public Safety | Jobs & Code Talk | Newsroom & Magazine
Contact Us | Privacy Policy | Vision, Mission & Values | Blueprint to the Future
Subsidiaries: ICC Evaluation Service | International Accreditation Service | ICC Foundation
© 2008 International Code Council

 

About ICC ICC Board Site Map Contact Us Help