| 01. |
GENERAL CONSTRUCTION PROVISIONS |
10% |
| |
0101. Grade and Structure
Elevations
Visually verify that the elevation of grade adjacent to the structure is as specified on approved construction documents. Visually verify floor elevation above adjacent grade is as specified on the approved construction documents. Visually verify vertical elevation of the construction to established grade elevations. |
|
| |
0102. Select Fill
Inspect properly compacted, select fill as specified on the approved construction documents. Verify that structural fill is not used in AV zones. |
|
| |
0103. Location of Construction on Property
& Construction Survey
Visually identify the property boundaries and location of the construction on the property as indicated on the approved plans. When specified by the building official, verify that construction is consistent with horizontal and vertical elements of the approved plans, as confirmed by a construction (tie-in) survey. |
|
| |
0104. Deep Foundation Piles
Review the certified pile reports to verify that deep foundation piles are installed to the design depth or to the point of refusal of further penetration, and that wood piles are treated to resist decay. |
|
| |
0105. Shear Walls
Inspect compliance of shear walls to approved construction documents and accepted coastal construction standards for the increased loads of wind and water. |
|
| |
0106. Product Approvals
For all products which require listing or product evaluation reports, verify that installation is in compliance with the listing or product evaluation report. |
|
| |
0107. Slope Stability & Erosion
Verify that construction on sloping property is designed to resist damage from erosion and slides. |
|
| |
0108. Special Inspection
Verify that special inspection documentation is provided. |
|
| |
0109. Corrosion Control
Verify that exposed metal connections are protected against corrosion per the approved construction documents and accepted construction practices. |
|
| 02. |
SPECIAL HIGH WIND PROVISIONS AND LOAD PATH CONTINUITY |
35% |
| |
0201. Load Path and
Connections - Foundation to Floor
Verify load-path continuity and inspect installation of connections from the foundation to the floor diaphragm. |
|
| |
0202. Load Path and
Connections - Floor to Walls
Verify load-path continuity and inspect installation of connections between the floor diaphragm and the walls. |
|
| |
0203. Load Path and
Connections - Between Stories
Verify load-path continuity and inspect installation of connections between stories. |
|
| |
0204. Load Path and Connections - Walls to
Roof/Ceiling
Verify load-path continuity and inspect installation of connections between walls and the roof and ceiling diaphragm. |
|
| |
0205. Load Path -
Gable End Construction
Verify load-path continuity and inspect installation of connections and lateral bracing of gable end construction. |
|
| |
0206. Structural
Hardware and Fasteners
Verify rating and identification of all structural hardware and proper use of fasteners. Verify that nailing equipment used to install structural hardware meets manufacturer's specifications. |
|
| |
0207. Structural
Lumber and Pre-Engineered Systems
Verify that structural lumber is treated to prevent decay, and complies with manufacturer's specifications for strength when used with the specified hardware. Verify that bracing and installation of pre-engineered framing systems are approved for use in the construction documents, and comply with the profile certificate provided by the manufacturer for installation in high-wind hazard areas. |
|
| |
0208. Wind Bourne Debris Regions
In windborne debris regions, verify that all openings have approved protection from windborne debris, including: windows; doors; garage doors; and skylights. Verify special high-wind or impact-resistant rating of opening protection. |
|
| |
0209. Special High-Wind
Roofing
Verify that sheathing, underlayment, and shingle fasteners follow manufacturer's recommendations for high-wind installations. Verify that all roof coverings meet relevant ASTM high-wind standards and comply with the approved construction documents. Verify adhesives comply with high-wind standards. |
|
| |
0210. Exterior Sheathing
and Wall Coverings
Verify that exterior sheathing and wall coverings and fasteners comply with the approved construction documents and manufacturer's recommendations for high-wind installations. |
|
| |
0211. Soffits, Overhangs
Verify that installation of soffits and overhangs comply with the approved construction documents and to accepted construction practices for high-wind installations. |
|
| |
0212. Structural Design Parameters
Verify correct use of structural design parameters. |
|
| 03. |
SPECIAL FLOOD HAZARD AREAS |
35% |
| |
0301. Substantial
Improvement and Damage
Provide substantial damage assessments on behalf of the code official following damage of any origin. Verify that substantial repairs and improvements to property comply with flood-plain management regulations, including the 50% Rule for older construction. |
|
| |
0302. Flood-Resistant
Materials
Verify use of flood-resistant materials below base flood elevation (BFE). |
|
| |
0303. Exterior Equipment
Verify that utilities and mechanical equipment which are located outside of the structure are installed above the base flood elevation (BFE) or are watertight, and are anchored in accordance with the approved construction documents. |
|
| |
0304. Breakaway Walls
Verify that breakaway walls in AV zones are constructed with approved materials and connections, and in accordance with the approved construction documents. |
|
| |
0305. Flood Vents
Verify that flood vents are installed as specified on the approved construction documents. |
|
| |
0306. Dry Floodproof
Enclosures Below Base Flood Elevation (BFE)
For non-residential construction, where dry flood proofing is specified verify that enclosures below base flood elevation are constructed or installed according to the design. |
|
| |
0307. Flood Resistant
Foundation Systems
Inspect compliance of deep-foundation systems in AV zones to approved construction documents and accepted construction practices. Inspect special coastal construction requirements of shallow foundations in zones to approved construction documents and accepted construction practices. |
|
| |
0308. Elevation Certificate
When specified by the building official, verify that an elevation certificate based on finished construction is provided prior to issuance of the certificate of occupancy. |
|
| |
0309. Use of Areas Below the Base Flood Elevation
Verify use of enclosed spaces below the base flood elevation are in accordance with requirements for coastal areas. |
|
| 04. |
DETACHED AND ATTACHED ACCESSORY STRUCTURES |
10% |
| |
0401. Decks and Patios
Verify that construction of building decks and patios are installed in compliance with the approved construction documents, and are structurally independent where required from the building foundation, as required. |
|
| |
0402. Manufactured
Housing Foundation and Anchoring Systems
Inspect construction of mandatory foundation systems for installation of manufactured housing for compliance with the approved construction documents. Inspect installation of mandatory structural anchoring systems for manufactured housing for compliance with the approved construction documents. |
|
| |
0403. Accessory Structures
Verify that all accessory structures installed in high-wind zones comply with structural and anchorage requirements of the building code. Verify that all accessory structures in flood hazard areas are elevated and anchored, as required by the building code. Report the presence of any non-permitted accessory structures. |
|
| |
0404. Docks, Wharfs, Piers and Sea Walls and
Bulkheads
Verify that construction and repair of boat docks, wharfs and piers comply with the approved construction documents. Inspect construction and repair of sea walls, bulkheads, tie-backs and deadmen in accordance with the approved construction documents. |
|
| 05. |
GOVERNMENTAL REGULATIONS |
10% |
| |
0501. Floodways
Verify that construction does not encroach into floodways unless permitted to assure that this will not increase the level of flooding. |
|
| |
0502. Designated
Wetlands
Verify that construction does not encroach into wetlands unless permitted by the appropriate agency. |
|
| |
0503. Coastal Construction
Setback/Control Lines
Verify that coastal construction complies with setback (Control Line) requirements. |
|
| |
0504. Administrative
Interpret and apply administrative provisions in coastal areas. |
|