ICC logo masthead graphic masthead graphic
 
masthead graphic
MembershipProduct StoreCodes & StandardsGovernment RelationsTrainingCertification and TestingConsumer SafetyJobs and Code TalkNewsroom and Events

Inspector  |  Contractor  |  Renewals  |  UST / AST Certification  |  Legacy / State



Certification: Fire Plans Examiner-Equivalent to NFPA 1031, Fire Plans Examiner I and II

Exam ID: F3
 
  • 60 multiple-choice questions
  • 3½-hour limit
  • Open book
Content Outline: A detailed outline of the subject matter covered by the exam, including the percentage of questions from each content area and task.
01. ADMINISTRATION
5%
 

0101. Permits
Review and process applications for operational and construction permits.

10%
 

0102. Correspondence
Prepare correspondence related to interpretation and application of department and code requirements.

5%
 

0103. Legal Enforcement
Prepare technical reports necessary to enforce violations of fire code requirements, including preparing violation notices and stop work orders.

10%
  0104. Research and Testimony
Research fire protection requirements for special construction, operations and materials. When directed by the fire code official, provide expert technical testimony on fire codes and standards.
20%  
  0105. Policies and Procedures For Plan Review
Document internal policies and procedures for conducting fire protection plans examination which assure fair and consistent quality of service and code compliance. Document due-process procedures for handling of disputes.
5%  
  0106. Consultation and Explanation
Assist in coordinating the activities of the Fire Code Official with the building official, zoning official, registered design professional, owner/developer, contractor, and public utilities.
30%  
  0107. Prepare and Maintain Records
Prepare and maintain a record of each fire protection plans examination which is conducted, including notices and orders issued, showing the findings and disposition of each.
20%  
02. OCCUPANCIES   15%
 

0201. Occupancy Type
Verify that the Occupancy Type of the building is correct.

15%
  0202. Type of Construction
Verify that the specified Type of Construction of the building is correct.
15%  
  0203. Occupant Load
Verify code compliance of the specified occupant load for individual rooms.
25%  
  0204. Specific Occupancy and Use Hazards
Verify code compliance to protect against hazards of specific occupancies and use.
20%  
  0205. Evaluate Special Fire Protection Features
Verify that special fire protection features such as fire-resistive materials and surface treatments, and clearance of combustibles surrounding the building are specified where where required.
25%  
03. HAZARDOUS MATERIALS 20%
  0301. Management Plan (list elements)
Review the Hazardous Materials Management Plan and Inventory Statement for compliance with code requirements for the prevention, control and mitigation of dangerous conditions related to storage, dispensing, use and handling of hazardous materials.
5%  
  0302. Material Safety Data Sheets
Verify that Material Safety Data Sheets are submitted on hazardous materials, and specify the material classification hazard. Verify correct classification of hazardous materials, and maximum allowable quantity.
10%  
  0303. Control Areas
Verify that control areas are specified where required, and are designed and constructed in accordance with the Code.
20%  
  0304. Special Hazards
Verify that occupancies with special hazards - such as Hazardous Production Material (HPM), semiconductor fabrication, drycleaning and woodworking - comply with specific Code requirements for these hazards. Verify that explosion control is provided where required.
15%  
  0305. Flammable and Combustible Liquids and Gases
Verify that storage, use and handling of flammable and combustible liquids and gases is specified, and complies with special Code requirements.
25%  
  0306. Storage of Combustibles
Verify the general fire protection and safety requirements for combustible storage.
25%  
04. FIRE PROTECTION 35%
  0401. Water Supply for Fire Protection
Verify that water supplying fire protection systems is sufficient for designed fire flow, with control and monitoring equipment as required by Code. Verify that hydrants are located and sized as required. Verify compliance of fire department inlet and hose connections.
15%  
  0402. Sprinklers, Standpipes and Alternate Automatic Fire Extinguishing Systems
Verify that sprinklers, standpipes and alternate automatic fire extinguishing systems are specified where required, are designed by qualified persons to the appropriate standard, are designed for the specified class of service, and are listed for the specified class of service, and are listed for their specified use. Verify compliance of construction and equipment specifications for layout, installation, operation and monitoring.
35%  
  0403. Fire Alarm and Detection Systems
Review that fire alarm and detection systems are specified where required, are designed by qualified persons to the appropriate standard, are designed for the specified class of service, and are listed for their specified use. Verify compliance of construction and equipment specifications for layout, installation, operation and monitoring.
35%  
  0404. Portable Extinguishers
Verify compliance of size, class and location of portable extinguishers.
5%  
  0405. Smoke Control Systems
Verify that mechanical and passive smoke control systems are specified where required, are designed by qualified persons to the appropriate standards.
10%  
05. EGRESS AND SAFETY (less significance to FPPE, verifies only) 25%
  0501. Emergency and Standby Power
Verify that emergency and standby power is provided for systems egress and Occupant safety, and are listed for the specified use.
5%  
  0502. Egress Doors
Verify that egress doors are provided where required, are of adequate size, swing, fire protection rating and compliance of panic or fire exit hardware.
25%  
  0503. Stairs, Ramps and Balconies
Verify that stairs, ramps and balconies comply with Code requirements, including rise/run of steps, width, length, guards, rails and landings.
25%  
  0504. Exit Access
Verify that the egress rout complies with Code requirements for width, clearances, maximum travel distance, fire protection, illumination and signage. Verify that any dead-end corridors comply with Code requirements.
30%  
  0505. Access To Buildings, Windows and Roofs
Verify that the building and its windows and roof are accessible for emergency access by the fire department. Verify stairway access to the roof when required by Code, with street-level signage. Verify that the site plan specifies location of premise identification and, when required, fire-department key boxes.
10%  
  0506. Hazards To Fire Fighters
Verify that posting of signage for hazardous materials is specified on the plans where required. Verify that protective barriers are specified where necessary for the safety of emergency personnel. Verify that building elements that may be hazard to emergency personnel are identified.
5%  

Return to certification category


 

Contact Information

1-888-ICC-SAFE (422-7233), ext.
Certification Examinations
33806
Certification Renewal
33815
MCP Certification Examinations
33806
CBO Examinations
33806
Contractor Examinations
33805
Legacy Examinations
33823
UST/AST Examinations
33823
Special Inspection Examinations
33823



Click for more information

 

 
Home | Membership | ICC Store | Codes & Standards | Government Relations
Training | Certification & Testing | Public Safety | Jobs & Code Talk | Newsroom & Magazine
Contact Us | Privacy Policy | Vision, Mission & Values | Blueprint to the Future
Subsidiaries: ICC Evaluation Service | International Accreditation Service | ICC Foundation
© 2008 International Code Council

 