| To transition from the (85) Structural Steel &
Welding Special Inspector Certification to the (S1)
Structural Steel & Bolting Special Inspector
Certification, click
here. |
|
| Exam ID: S1 |
| |
- 90 multiple-choice questions - 60 code / 30 structural
plan reading
- 2 Part Examination (a passing score on both at
the same time)
- 3½-hour limit - recommended allocation of
time is 2 hours for code portion and 1½ hours
for plan portion
- Open book
|
| Sample Examination Questions: The
sample questions are provided to give you an idea of the
style and format of examination questions. The questions
are not intended to represent content, references or questions
that will be on the examination. They are not intended
nor should they be referenced/used as a study tool for
the examination. |
| 1. |
According to the specification for structural
joints using high-strength bolts, the nominal diameter
of standard bolt holes shall be _____ inch larger than
the nominal bolt diameter. Click for Answer
|
| |
|
A. |
1/32 |
| |
|
B. |
1/16 |
| |
|
C. |
5/32 |
| |
|
D. |
1/8 |
| 2. |
According to the specification for structural
joints using high-strength bolts, the minimum length of
a high strength bolt shall be such that the end of the
bolt is _____ the outside face of the nut when completely
installed. Click for Answer
|
| |
|
A. |
flush with |
| |
|
B. |
2 threads below |
| |
|
C. |
2 threads beyond |
| |
|
D. |
within 1/16 inch below |
| 3. |
According to the building code, the responsibilities
of the special inspector include all of the following
except: Click for Answer
|
| |
|
A. |
applying for all required permits. |
| |
|
B. |
submitting final reports of compliance. |
| |
|
C. |
reading and understanding plans and specifications. |
| |
|
D. |
reading and understanding applicable codes
and standards. |
| 4. |
According to the Specification for Structural
Joints using A325/A490 bolts, the minimum number of hardened
washers required in a slip-critical joint when an ASTM
A490 bolt is used to connect ASTM A36 steel members is
_____. Click for Answer
|
| |
|
A. |
1 |
| |
|
B. |
2 |
| |
|
C. |
3 |
| |
|
D. |
4 |
| 5. |
According to the specification for structural
joints using high-strength bolts, in slip-critical connections
the surface of joints which are specified for painting
shall be: Click for Answer
|
| |
|
A. |
blast cleaned. |
| |
|
B. |
cleaned by hand wire brushing. |
| |
|
C. |
cleaned by power wire brushing. |
| |
|
D. |
roughened by abrasive cloth or sandpaper. |
|
|
|
|
Return to certification category
|