| 01. |
Release Detection (Content Area) |
32% |
| |
0101. Tank Release Detection (Task)
Verify correct method of release detection is in place and that all required periodic testing & maintenance is performed at the required frequency. Verify that any leak detection devices and equipment are operational and have third party certification if applicable. |
18% |
|
| |
0102. Piping Release Detection (Task)
Verify correct method of release detection is in place and that all required periodic testing & maintenance is performed at the required frequency. Verify that any leak detection devices and equipment are operational and have third party certification if applicable. |
14% |
|
| 02. |
Corrosion Protection (Content Area) |
|
12% |
| |
0201. Sacrificial Anode Cathodic Protection (Task)
Verify the sacrificial anode systems are operational and that cathodic protection testing is performed at required intervals. |
4% |
|
| |
0202. Impressed Current Cathodic Protection (Task)
Verify the impressed current systems are operational and that cathodic protection testing is performed at required intervals. |
4% |
|
| |
0203. General Corrosion Protection
Verify that tanks without cathodic protection meet corrosion protection requirements |
4% |
|
| 03. |
Construction Standards for Aboveground Storage Tanks |
20% |
| |
0301. Pumping Systems (Task)
Verify proper operation of suction, pressurized, return and other pumping systems and electrical controls. |
2% |
|
| |
0302. Emergency Shut-Off (Task)
Verify that emergency shut-off switch is installed where required. |
4% |
|
| |
0303. Emergency Vent System (Task)
Verify that emergency vents are provided and that vent pipe size is adequate. |
4% |
|
| |
0304. Miscellaneous Construction Standards
Verify tank that safety equipment is installed, including vehicle impact protection and security |
10% |
|
| 04. |
Corrective Action Account & Financial Responsibility Account |
8% |
| |
0401. Statutory Responsibilities (Task)
Verify that the AST System Operator take appropriate action to comply with Article 14, Wyoming Environmental Act. |
8% |
|
| 05. |
Overfill Prevention, Spill Prevention, and Release Reporting |
12% |
| |
0501. Overfill and Spill Prevention (Task)
Take appropriate action to prevent overfills and spills |
6% |
|
| |
0502. Release Reporting (Task)
Report releases according to state laws and rules |
6% |
|
| 06. |
General Operating Requirements |
16% |
| |
0601. Inspections, Emergency Equipment, Maintenance & Clean-up (Task)
Inspect hardware such as nozzles, breakaway couplings, hoses and impact valves. Verify emergency equipment fire extinguishers, fire suppression systems & alarm pull boxes in place & operational. Determine the proper action to take to clean up and handle product spills. Provide training of facility employees. |
8% |
|
| |
0602. Fuel Tax Licensing (Task)
Identify what type of license is required |
2% |
|
| |
0603. Record Keeping Maintain records of inspections, test, maintenance, etc. |
6% |
|