International Building Code®
Chapter 2 Definitions
Chapter 2 provides definitions for terms used throughout the IBC. These definitions provide a common language for designing buildings to resist severe wind events. They help us understand wind hazard intensity, determine the forces buildings must withstand and describe the structural systems and connections needed to create a continuous load path. Together, they ensure that buildings are designed with appropriate safety factors, sturdier connections and stronger performance in high-risk areas.
Chapter 4 Special Detailed Requirements Based on Occupancy and Use
Section 423 Storm Shelters: This entire section applies to the design and construction of storm shelters constructed as separate detached buildings or constructed as rooms or spaces within buildings for the purpose of providing protection from tornadoes, hurricanes and other severe windstorms during the storm. This section specifies where storm shelters are required and provides requirements for the design and construction of storm shelters.
- 423.2 Construction – storm shelters are to be constructed in accordance with this code and ICC 500 and shall be designated as hurricane shelters, tornado shelters or combined hurricane and tornado shelters.
- 423.3 Occupancy classification – occupancy classifications for storm shelters are determined based on whether the shelter is a dedicated storm shelter, a storm shelter within a host building, its design occupancy load and its location relative the building(s) it services.
Chapter 9 Fire Protection and Life Safety Systems
Section 909 Smoke Control Systems
- 909.4.1 Smoke control – stack effect. Smoke control system is designed so normal or reverse stack effect doesn't interfere is the system's capabilities.
- 909.4.3 Smoke control – wind effect. Smoke control system design considers adverse wind effects.
- 909.20.4 Smoke control - stairway and ramp pressurization. Pressurization relative to stairway and ramp
Section 913 Fire Pumps
- 913.2 Fire pumps – interruption of service. Protection of fire pump, driver and controller against service interruption through damage caused by windstorm, flood and other special weather and environmental conditions.
Chapter 10 Means of Egress
Section 1031 Emergency Escape and Rescue
- 1031.2 Where required – storm shelter exception. Storm shelters are excepted to include emergency escape and rescue openings.
Chapter 11 Accessibility
Section 1112 Signage
- 1112.5.2 Variable message signs – emergency shelters. Emergency shelters must provide variable message signage conveying emergency-related information.
Chapter 14 Exterior Walls
Section 1402 Performance Requirements
- 1402.3 Performance requirements - wind resistance. Exterior walls and coverings, soffits and associated openings designed to resist superimposed loads.
Section 1404 Installation of Wall Coverings
- 1404.12.1 Attachment. Exterior metal veneer attachment fastenings and their spacing designed to resist wind loads specified in Section 1609.
- 1404.15 Vinyl siding and insulated vinyl siding - design wind pressure requirements. Vinyl siding permitted on exterior walls where the design wind pressure does not exceed 30 psf., or else compliance with Chapter 16.
- 1404.15.2 Installation over foam plastic insulated sheathing - design pressure requirements. Vinyl siding over foam plastic sheathing to comply with Section 1404.15 and have wind load design pressure rating in accordance with Table 1404.15.2.
- 1404.17 Fiber cement siding. Fiber-cement siding permitted on exterior walls for wind pressure resistance or basic wind speed exposures as indicated by the manufacturer's listing and installation instructions.
- 1404.18 Polypropylene siding. Polypropylene siding is limited to exterior walls in areas meeting maximum basic wind speeds specified in Chapter 16, with building height considerations.
Section 1406 Metal Composite Material (MCM)
- 1406.4 Structural design. Metal composite materials designed and constructed to resist wind loads as required by Chapter 16 for components and cladding.
- 1406.5 Approval. Results of approved tests or engineering analysis to be submitted to the building official for compliance verification with Chapter 16 for wind loads.
- 1406.6 Weather resistance. MCM systems must be designed and constructed to resist wind and rain in accordance with this section and manufacturer's installation instructions.
Section 1407 Exterior Insulation and Finish Systems (EIFS)
- 1407.3 Structural design. Underlying structural framing and substrate to be designed and constructed to resist loads as required by Chapter 16.
- 1407.4 Weather resistance. System designed and constructed to resist wind and rain in accordance with this section and manufacturer's application instructions.
Section 1408 High-Pressure Decorative Exterior-Grade Compact Laminates (HPL)
- 1408.4 Structural design. HPL system to be designed and constructed to resist wind loads as required by Chapter 16 for components and cladding.
- 1408.5 Approval. Results of approved tests or engineering analysis to be submitted to the building official for compliance verification with Chapter 16 for wind loads.
- 1408.6 Weather resistance. HPL systems must be designed and constructed to resist wind and rain in accordance with this section and manufacturer's installation instructions.
Section 1409 Insulated Metal Panel (IMP)
- 1409.2 Structural design. Structural design of IMP system to be in accordance with this section.
- 1409.3 Weather resistance. IMP systems must be designed and constructed to resist wind and rain in accordance with this section and manufacturer's installation instructions
Section 1412 Soffits and Fascias at Roof Overhangs
- 1412.2 General wind requirements. Soffits and fascias capable of resisting components and cladding loads for walls in accordance with Chapter 16 using an effective wind area of 10 square feet.
- 1412.3 Vinyl & aluminum soffit panels. Vinyl and aluminum soffit panels to meet fastener and installation instruction requirements based on required design wind pressures.
- 1412.5 Hardboard soffit panels. Hardboard soffit panel minimum thickness and installation instruction requirements to meet required design wind pressures.
- 1412.7 Aluminum fascia. Aluminum fascia to meet minimum thickness and manufacturer's installation instruction requirements.
Chapter 15 Roof Assemblies and Rooftop Structures
Section 1504 Performance Requirements
- 1504.1 Wind resistance of roofs. Roof decks and roof coverings to be designed in accordance with Section 1504.
- 1504.2 Wind resistance of asphalt shingles. Asphalt shingles tested to ASTM D7158 and meet classification requirements of Table 1504.2 for maximum basic wind speed.
- 1504.3 Wind resistance of clay and concrete tile. Wind loads on clay and concrete tile roof coverings to be in accordance with Section 1609.6.
- 1504.4 Wind resistance of nonballasted roofs (includes built-up, modified bitumen, fully adhered/mechanically attached, metal shingles, metal panels, and slate). Roof coverings mechanically attached to the roof deck to be designed to resist design wind load pressures with Section 1609.6.2.
- 1504.5 Ballasted low-slope single-ply roof systems. Ballasted low-slope single-ply roof system coverings to be installed in accordance with Section 1507.12 and designed to ANSI/SPRI RP-4.
- 1504.6 Edge systems for low-slope roofs. Metal edge systems installed on specific low-slope roof systems to be designed and installed for wind loads to Chapter 16 and certain test standards.
- 1504.8 Wind resistance of aggregate-surfaced roofs – parapets. Parapets provided for aggregate surfaced roofs and comply with Table 1504.8 and include installation location requirements.
Section 1507 Requirements for Roof Coverings
-
- 1507.1.1 Underlayment. Underlayment requirements based on roof covering materials through this section and 3 associated Table 1507.1.1 tables.
- 1507.3.7 Clay and concrete tile attachment. Clay and concrete roof tiles to be fastened in accordance with Table 1507.3.7.
- 1507.16.8 Building Integrated Photo Voltaic (BIPV) shingles - wind resistance. Shingles
- to comply with requirements of Table 1504.2 for the appropriate maximum basic wind speed.
1507.17.4 Building Integrated Photo Voltaic (BIPV) panels – underlayment. Addresses underlayment application method and 1507.4.1 further addresses high-wind attachment requirements.
Chapter 16 Structural Design
Section 1602 Notations
- 1602.1 Notations (abbreviations). Chapter notations defined.
Section 1603 Construction Documents
- 1603.1.4 Wind design data. Construction documents for wind design data.
Section 1604 General Design Requirements
- 1604.3 Serviceability . General design requirements for structural systems and members.
- 1604.5 Risk category. Building risk category is established based on Table 1604.5
- 1604.8 Anchorage. Buildings must have anchorage in accordance with Sections 1608.1 through 1604.8.3.
- 1604.9 Wind and seismic detailing. Lateral force-resisting systems to meet seismic detailing requirements where wind load effects are greater than seismic load effects.
- 1604.10. Loads on storm shelters. Loads and load combinations on storm shelters to be determined in accordance with ICC 500.
Section 1605 Load Combinations: Requirements in this section address a building's strength load combinations.
Section 1609 Wind Loads: Requirements in this section address a building's minimum wind load designs.
- 1609.5 Tornado loads. Map of U.S. showing the tornado-prone region.
Section 1612 Flood Loads
- 1612.4 Flood hazard documentation. Outlines design documentation criteria for construction in coastal high hazard and coastal A zones.
Chapter 17 Special Inspections and Tests
Section 1704 Special Inspections and Tests, Contractor Responsibility and Structural Observation
- 1704.3.3 Statement of special inspections – wind requirements. Statement identifying the designated seismic and seismic force-resisting systems subject to special inspections or tests.
Section 1705 Required Special Inspections and Tests
- 1705.12. Special inspections for wind resistance. Required wind exposure categories where special inspections for wind resistance is required.
Section 1709 Preconstruction Load Tests
- 1709.5 . Exterior window and door assemblies – wind pressure requirements. Pre-construction load tests - design pressure rating requirements for exterior windows and doors.
Chapter 18 Soils and Foundations
Section 1806 Presumptive Load-Bearing Values of Soils
- 1806.1 . Presumptive load-bearing values of soils - load combinations. Requirements for load-bearing values used with the allowable stress design load combinations
Section 1810 Deep Foundations
- 1810.3.2.6 Design and detailing – materials – allowable stresses. Maximum allowable stresses for materials used in deep foundations as listed in Table 1810.3.2.6.
- 1810.3.3.1.5 Design and detailing – determination of allowable loads – allowable axial load – uplift capacity of single deep foundation element. Uplift capacity of a single deep foundation element to be determined by an approved method of analysis
Chapter 21 Masonry
Section 2109 Empirical Design of Adobe Masonry
- 2109.1.1 Empirical design of Adobe masonry – limitations. Adobe masonry design limitations based on specified Sections in this code, TMS 402-16 modification for wind
Chapter 23 Wood
Section 2304 General Construction Requirements
- 2304.6 Exterior wall sheathing. Wood products used as exterior wall sheathing and their connections must be designed and installed according to the maximum basic wind speed and wind pressures in this section.
Section 2305 General Design Requirements for Lateral Force-Resisting Systems: Lateral force-resisting systems using wood products in shear walls and diaphragms must meet the design requirements of this section.
Section 2306 Allowable Stress Design: This section addresses allowable stress designs for a variety of wood products and applications.
Section 2307 Load and Resistance Factor Design: When using load and resistance factor design, wood elements and structures must meet the requirements of ANSI/AWC NDS and AWC SDPWS.
Section 2308 Conventional Light-Frame Construction
- 2308.2 Limitations. Buildings of light-frame construction must be designed and constructed in accordance with the wind and load requirements of this section which include provisions for tornado loads.
- 2308.11.4 Roof and ceiling framing. Roof construction must be attached to the wall below with connections capable of resisting the required uplift loads according to the table or the truss design drawings.
Chapter 24 Glass and Glazing
Section 2404 Wind, Snow, Seismic and Dead Loads on Glass
- 2404.1 Vertical glass. Vertical glass (sloped 15 degrees or less from vertical) in exterior applications must be designed to resist wind loads in accordance with the requirements in section 1609.
- 2404.2 Sloped glass. Glass sloped more than 15 degrees from vertical in exterior applications must be designed to resist the most critical load combination determined by the equations in this section.
- 2404.3 Wired, patterned, and sandblasted glass (vertical and sloped). Wired, patterned and sandblasted glass, both vertical and sloped, in exterior applications must be designed to resist wind loads according to section 1609 and the equations in this section.
Chapter 25 Gypsum Panel Products and Plaster
Section 2505 Shear Wall Construction: Gypsum panel products and plasters used in shear wall assemblies must comply with this section.
Section 2508 Gypsum Construction
- 2508.6 Horizontal gypsum panel product diaphragm ceilings. Gypsum panel products used in horizontal diaphragm ceilings must meet the requirements of this section.
Chapter 26 Plastic
Section 2603 Foam Plastic Insulation
- 2603.10 Wind resistance. Foam plastic insulation used as sheathing must comply with wind resistance required by ANSI/SBCA FS 100.
Chapter 30 Elevators and Conveying Systems
Section 3001 General
- 3001.6 Structural design. Elevators, escalators and other conveying systems must be designed according to the applicable wind load requirements of section 1609.
Chapter 31 Special Construction
Section 3102 Membrane Structures
- 3102.7 Engineering design. Membrane structures must be designed to sustain a variety of loads, including the wind loads specified in Chapter 16.
Section 3103 Temporary Structures
- 3103.6.1.2 Structural requirements – structural loads – wind loads. Design wind loads for public-occupancy temporary structures, like tents and bleachers, may be reduced by the factors listed in this section and the accompanying table.
- 3103.8 Controlled occupancy procedures. Where controlled occupancy procedures are required for a public-occupancy temporary structure, wind speeds must be monitored before and during occupancy, and the structure must be vacated if the design wind speed is expected to be exceeded.
Section 3105 Awnings and Canopies
- 3105.2 Design and construction. Awnings and canopies must be designed to handle wind loads as required in Chapter 16.
Section 3111 Solar Energy Systems
- 3111.1.1 General - wind resistance. Roof-mounted photovoltaic systems and solar thermal collectors must be designed according to section 1609.
Section 3113 Relocatable Buildings
- 3113.2 Supplemental information. Information submitted to the AHJ for relocatable buildings must include the design loads specified in this section.
- 3113.3 Manufacturer's data plate. The manufacturer's data plate on relocatable buildings must include the design loads specified in this section.
Section 3114 Intermodal Shipping Containers
- 3114.8 Structural. Intermodal shipping containers that conform to ISO 1496-1 to be used as buildings or structures must be designed to meet Chapter 16 and this section.
Chapter 33 Safeguards During Construction
Section 3306
- 3306.9 Adjacent to excavations. Barriers adjacent to excavation sites must be designed to resist wind pressures specified in Chapter 16.