BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//ICC - ECPv6.15.17.1//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:ICC
X-ORIGINAL-URL:https://www.iccsafe.org
X-WR-CALDESC:Events for ICC
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/Chicago
BEGIN:DAYLIGHT
TZOFFSETFROM:-0600
TZOFFSETTO:-0500
TZNAME:CDT
DTSTART:20230312T080000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
TZNAME:CST
DTSTART:20231105T070000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0600
TZOFFSETTO:-0500
TZNAME:CDT
DTSTART:20240310T080000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
TZNAME:CST
DTSTART:20241103T070000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0600
TZOFFSETTO:-0500
TZNAME:CDT
DTSTART:20250309T080000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
TZNAME:CST
DTSTART:20251102T070000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=America/Chicago:20240806T110000
DTEND;TZID=America/Chicago:20240806T120000
DTSTAMP:20260512T101933
CREATED:20240726T145435Z
LAST-MODIFIED:20240726T145515Z
UID:566015-1722942000-1722945600@www.iccsafe.org
SUMMARY:Use of Grade 80 and Grade 100 Reinforcing Bars in ACI 318-19
DESCRIPTION:Recent advances\, including substantial new research\, have enabled reinforcing steels of higher strengths to be a viable option in a variety of applications in reinforced concrete structures. This webinar presents information related to the use of Grade 80 and Grade 100 steel reinforcement in the 2019 edition of ACI 318 Building Code Requirements for Structural Concrete. Numerous revisions have been made in ACI 318-19 to incorporate the use of high-strength reinforcement\, and this webinar covers new and updated requirements for the following: \n\nTypes of nonprestressed reinforcing bars\nDevelopment and splice lengths\nStructural members\, including two-way slabs\, beams\, columns\, walls\, diaphragms\, and foundations\nLimits on concrete compressive strength\nStrength reduction factors\n\nBenefits related to the use of Grade 80 and Grade 100 reinforcing bars are also included. \nIndustry professionals should find the information in this webinar useful when designing\, detailing\, and specifying Grade 80 and Grade 100 reinforcing bars in building projects. \nRegister here. \n11:00 A.M. – 12:00 P.M. PT
URL:https://www.iccsafe.org/news-and-events-calendar/use-of-grade-80-and-grade-100-reinforcing-bars-in-aci-318-19/
LOCATION:TN
CATEGORIES:Education Calendar
ORGANIZER;CN="S. K. Ghosh Associates":MAILTO:kbhaumik@skghoshassociates.com
END:VEVENT
END:VCALENDAR