Skip to Main Content
Building Safety Journal Logo

Building Safety Journal - International Code Council

Main Menu

Menu

      • April, 2025 Articles
      • March, 2025 Articles
      • February, 2025 Articles
      • January, 2025 Articles
      • December, 2024 Articles
      • November, 2024 Articles
      • 2025 Articles
      • 2024 Articles
      • Deep Dives
      • Member News
      • Personal Perspectives
      • Quick Hits
      • Technical Topics
      • Press Releases
      • Sponsored Content
      • View All
      • Buildings, Construction, Architecture/Design
      • Fire, Wildland-Urban Interface
      • Plumbing, Mechanical, Fuel Gas, Pools/Spas
      • Energy, Solar, Green, Sustainability
      • Disaster Preparedness, Mitigation, Resiliency
  • Subscribe
    • ICC Family of Solutions
    • ICCSafe
    • myICC
    • Digital Codes
    • cdpACCESS
    • Store
    • Support

Join today!

Keep up-to-date on crucial industry news, innovative training and expert technical advice with a free subscription to the award-winning Building Safety Journal.

Subscribe

Sign In or Register Here

Provide your email address
Provide your password
Answer the math challenge
Please enter your e-mail address below. We will email you a link to reset your password.
Provide your email address
Answer the math challenge
To complete your registration, please verify your email address.
Answer the math challenge

We have emailed the address you provided. Please click the link in the email to confirm your email address.

Your account has been marked for password reset. Please change your password.
Provide your new password
Verify your new password
Answer the math challenge 5 minus three

Only registered ICC members have access to this article at this time.

Explore all the benefits that ICC Membership has to offer and become a member today to gain access to this exciting content.

If you're already an ICC member Sign In Now.

Can We Help?

  • Reset My Password
  • I Need More Help

Code requirements for outdoor kitchens

July 11th, 2021
by Glenn Mathewson
  • Technical Topics

Barbecue grills shoved into a corner of the deck have evolved into full-blown outdoor kitchens. As a “code guy,” I should point out that the International Residential Code (IRC) has a few things to say about kitchens, and it doesn’t care if the kitchen is inside or outside the house.

 

Cooking with gas

The gas pipe stub needs to extend high enough above the finished decking so that a minimum of 2 inches of unthreaded pipe is exposed. On a low deck like this, it is a good idea to paint the pipe prior to decking installation. Photo: Glenn Mathewson
The gas pipe stub needs to extend high enough above the finished decking so that a minimum of 2 inches of unthreaded pipe is exposed. On a low deck like this, it is a good idea to paint the pipe prior to decking installation. Photo: Glenn Mathewson

Other than following all of the manufacturer’s installation instructions and using only tested and listed appliances, there are no specific code requirements for built-in or freestanding BBQ grills. That said, be sure to observe minimum clearances when designing the space, to minimize the risk of fire. Look for eaves extending beyond sidewalls and possibly over the grill, and be careful when designing a porch roof over a grill area. An exhaust hood can be expensive, but it is effective at managing smoke when the grill is under a roof or near a window and may prevent smoke from entering the home and triggering the alarm system.

Building codes definitely apply when a gas distribution system from the home is extended to permanently serve the outdoor grill. Regardless of licensure requirements, which vary from state to state, only trained and professional plumbers or mechanical contractors should install gas lines; however, there are a few things you as the designer should understand and consider. First, make sure the construction schedule allows for painting the common black iron gas pipe for protection from corrosion.

The plumber also needs to be guided on how far to stub the line up from beneath the deck, and that means knowing the thickness of the decking. In order to tighten the threaded fittings on gas pipe, a pipe wrench needs sufficient unthreaded pipe to clutch. The IRC requires that the gas pipe extend through the floor enough to expose a minimum of 2 inches of unthreaded pipe. Simple to do, but simple to overlook. Also, the pipe stub cannot be located behind a door, where it would be subject to physical damage should the door repetitively be opened into the pipe.

 

Electrical convenience

While the IRC requires that all kitchens be provided with two 20-amp circuits dedicated to receptacle outlets, I have never heard of an inspector requiring this on an outdoor kitchen. The requirement for these receptacle circuits is to minimize the need for extension cords or receptacle splitters to serve toasters, blenders, and other small appliances commonly used in a kitchen. For the optional (and often seasonal) outdoor kitchen, these appliances—and the outlets needed to supply power to them—are not commonplace. Of course, if you choose to include receptacles in your design, installation would need to follow standard requirements.

While the IRC requires that all kitchens be provided with two 20-amp circuits dedicated to receptacle outlets, I have never heard of an inspector requiring this on an outdoor kitchen. The requirement for these receptacle circuits is to minimize the need for extension cords or receptacle splitters to serve toasters, blenders, and other small appliances commonly used in a kitchen. For the optional (and often seasonal) outdoor kitchen, these appliances—and the outlets needed to supply power to them—are not commonplace. Of course, if you choose to include receptacles in your design, installation would need to follow standard requirements.

 

Water

The installation of an outdoor sink is not commonplace, so discussion with the local building department during the planning phase is critical. Many details regarding the freshwater supply and drain for waste will be dependent on locally established rules and the climate, and not the IRC.

In freeze-prone areas, water can be supplied by a seasonal service similar to a landscape sprinkler system, with a stop and waste valve installed in the conditioned portion of the house that can be shut off and the outdoor piping drained when the weather turns cold. For year-round water service, the sink will need to be placed against the exterior wall of the house and supplied with a hot-cold frost-protected hose bibb. Of course, adding a sink to retain water introduces the need for a drain.

In some areas, code might not specifically prohibit simply draining the sink to the yard, but it may still raise a red flag with the inspector. No one cares if you wash your hands in your sink, and it drains to your yard, but what about washing the cutting board after prepping chicken shish kabobs out on the deck? To avoid this problem, a drain can be permanently connected to the home’s DWV (drain, waste, and vent) system, which requires the use of a P-trap to separate the occupant using the sink from the sewer system below the ground. But a P-trap can freeze, and while there are a number of ways to address this issue, the building department could question all of them.

Outdoor kitchen design and features can vary considerably and thus so do the IRC requirements regarding their installation. Keeping in mind the environmental differences between an outdoor kitchen and an indoor kitchen and considering the IRC can’t protect us from every possible hazard, just the probable, will help you get off on the right step in your design. However, many features of an outdoor kitchen could be uncommon to your building department, so always consult with it first.

 

This article originally appeared in the Sept. 10, 2018, issue of Deck Builder Magazine and is reprinted with permission.


Originally produced and published by the source linked to above, who is solely responsible for its content. Any facts, opinions or claims expressed in this article are based on the author and do not necessarily reflect those of the International Code Council. The Building Safety Journal is presenting this content to raise awareness of information publicly available online and does not verify the accuracy of any facts, claims or opinions made in the article.

 

About the Author
Glenn Mathewson
Glenn Mathewson, MCP, is a consultant and educator with BuildingCodeCollege.com. He has authored over 70 technical articles in publications such as Professional Deck Builder, The Journal of Light Construction, Fine Homebuilding and the Building Safety Journal, as well as the International Code Council’s book, Deck Construction Based on the 2009 International Residential Code. He represented the decking industry in the ICC code development process for the creation of many of the deck provisions first published in the 2015 IRC and again for the 2021 IRC. He is a professional speaker and educator in residential codes, with audiences ranging from contractors to building officials at both public and private events.
Submissions
Check out upcoming BSJ topics and send us articles for consideration:
Or send by email

Want to advertise in the BSJ?
Click Here

Share on Facebook
Facebook
Tweet about this on Twitter
Twitter
Share on LinkedIn
Linkedin

  • 25 24862 MTS CLE BSJ WAD 270X270 FINAL
  • 25 24731 BSM BSJ Website 270x270 WAD FINAL
  • 25 24651 TRN WDS BSJ BSJW WAD 270x270 FINAL a
  • tile 3
  • 25 24699 PD TRN SKGA Sub Plan BSJ WAD FINAL 270 x 270 2
International Code Council
International Code Council
International Code Council
International Code Council

Subscribe to the Building Safety Journal

Subscribe

Connect with Us

  • LinkedIn
  • Facebook
  • X
  • YouTube
  • Instagram

ICC Family of Solutions

  • Privacy Policy
  • Terms of Use
  • Contact Us
  • Accessibility Policy
UitUIDbJeErG9ZG3ZEspGg6ex4DQ2TJujAg0tOC5pPI=.html