Skip to Main Content
Building Safety Journal Logo

Building Safety Journal - International Code Council

Main Menu

Menu

      • April, 2025 Articles
      • March, 2025 Articles
      • February, 2025 Articles
      • January, 2025 Articles
      • December, 2024 Articles
      • November, 2024 Articles
      • 2025 Articles
      • 2024 Articles
      • Deep Dives
      • Member News
      • Personal Perspectives
      • Quick Hits
      • Technical Topics
      • Press Releases
      • Sponsored Content
      • View All
      • Buildings, Construction, Architecture/Design
      • Fire, Wildland-Urban Interface
      • Plumbing, Mechanical, Fuel Gas, Pools/Spas
      • Energy, Solar, Green, Sustainability
      • Disaster Preparedness, Mitigation, Resiliency
  • Subscribe
    • ICC Family of Solutions
    • ICCSafe
    • myICC
    • Digital Codes
    • cdpACCESS
    • Store
    • Support

Join today!

Keep up-to-date on crucial industry news, innovative training and expert technical advice with a free subscription to the award-winning Building Safety Journal.

Subscribe

Sign In or Register Here

Provide your email address
Provide your password
Answer the math challenge
Please enter your e-mail address below. We will email you a link to reset your password.
Provide your email address
Answer the math challenge
To complete your registration, please verify your email address.
Answer the math challenge

We have emailed the address you provided. Please click the link in the email to confirm your email address.

Your account has been marked for password reset. Please change your password.
Provide your new password
Verify your new password
Answer the math challenge 5 plus one

Only registered ICC members have access to this article at this time.

Explore all the benefits that ICC Membership has to offer and become a member today to gain access to this exciting content.

If you're already an ICC member Sign In Now.

Can We Help?

  • Reset My Password
  • I Need More Help

PHTA-10: The elevated pool standard – What it says, what it means

The ANSI/PHTA/ICC-10 2021 American National Standard is the first recognized standard or code to specifically address elevated pools or spas

May 27th, 2022
by Mark Trapani
  • Technical Topics

In August 2021, the American National Standards Institute (ANSI) approved the ANSI/PHTA/ICC-10 2021 American National Standard for Elevated Pools, Spas and Other Aquatic Venues Integrated into a Building or Structure. This is a major development since this is the first recognized standard or code to specifically address elevated pools or spas. This new standard focuses on several areas, the most significant of which is the need for a secondary containment system in order to prevent water infiltration into the structure below.

Elevated pools and spas have been around for decades. Just as with any in-ground pool, a leak can occur in an elevated pool, due to the pump, a misplaced filter cap or a pipe break. When an in-ground pool has a minor leak, the water will end up in the ground and does not typically cause significant damage to the property. When an elevated pool has a leak, unless a secondary containment system is present, the water can infiltrate whatever lies beneath and cause substantial damage to the building’s electrical system, to units beneath the pool and their belongings, or even to the structural integrity of the building. When water (especially salt or chlorinated water) infiltrates concrete and reaches the rebar, it can cause unwanted corrosion.

This is why a secondary containment system is imperative to building safety. A secondary containment system is designed to catch any leaking water and direct it away from the places it shouldn’t go. It may work just like a catch pan under a washing machine or water heater, for example.

There are presently many ways to design a secondary containment system. For this reason, and to allow for new methods in the future, the PHTA-10 standard does not prescribe any specific design or type of secondary containment system. One method presently available is the waterproof membrane used on a building rooftop to prevent rain or snow from entering.

Another important provision in the PHTA-10 standard is the requirement that all potential leak points be accessible for inspection and repair. The PHTA-10 standard states that any penetrations through the pool wall need to be accessible so that they can be inspected and repaired. If a pool or spa is leaking and you can’t access the leak point, then you can’t repair it, and that could lead to major problems.

While most jurisdictions that adopt the PHTA standard will likely target new construction, review and retrofitting of existing elevated pools should also be considered. And while the cost of installing a secondary system may be significant, the cost of doing nothing may be much greater.

You may be wondering who is responsible for understanding and following the PHTA-10 standard. The short answer is — everyone involved in the design, installation and maintenance of an elevated pool or spa. This includes architects, engineers, facility managers, code inspectors, code officials and anyone else who interacts with the elevated pool or spa. All should have a good understanding of the standard, so the pool or spa is designed and installed correctly the first time and properly maintained and inspected.

With the PHTA-10 standard now available, state and local governments can begin to adopt codes that address it. A standard is only effective where it is adopted, followed and enforced. Therefore, the development of the PHTA-10 standard cannot immediately eliminate all water infiltration episodes. It is, however, a giant step in this direction. As awareness about the importance of secondary containment spreads, we hope that new and existing facilities will take heed and that problems and disasters can be prevented in the future.

If you are interested in learning more about the PHTA-10 standard, Derek Downey, co-chair of the drafting committee and president of LegalPools.com, and I will be presenting at the 2022 World Aquatic Health Conference, taking place Oct. 12-14, 2022, in Houston, Texas, on how this new standard applies to inspectors, facility managers and others responsible for compliance and safety.

To learn more about, read or purchase a copy of the PHTA-10 standard, please visit the Pool & Hot Tub Alliance (PHTA). This standard will be referenced in the 2024 International Swimming Pool and Spa Code, a document PHTA publishes in collaboration with the International Code Council.

 

About the Author
Mark Trapani is the founder and managing member of UpStream Pools in Fairfield, New Jersey, providing consulting on installation planning, defect remediation and owner representation for elevated pools. He has installed, serviced, maintained and consulted on hundreds of elevated pools in New York City and nationally. A United States Air Force veteran, he has a bachelor's and master's degree in engineering. He is the PHTA-10 Standard Writing Committee Chair, holds the PHTA Certified Builder Professional certification and serves on the PHTA Commercial Council. His focus is on improving the performance of elevated pool installations by facilitating the creation and implementation of standards and by providing consulting and training on best practices.
Submissions
Check out upcoming BSJ topics and send us articles for consideration:
Or send by email

Want to advertise in the BSJ?
Click Here

Share on Facebook
Facebook
Tweet about this on Twitter
Twitter
Share on LinkedIn
Linkedin

  • 25 24862 MTS CLE BSJ WAD 270X270 FINAL
  • 25 24731 BSM BSJ Website 270x270 WAD FINAL
  • 25 24651 TRN WDS BSJ BSJW WAD 270x270 FINAL a
  • tile 3
  • 25 24699 PD TRN SKGA Sub Plan BSJ WAD FINAL 270 x 270 2
International Code Council
International Code Council
International Code Council
International Code Council

Subscribe to the Building Safety Journal

Subscribe

Connect with Us

  • LinkedIn
  • Facebook
  • X
  • YouTube
  • Instagram

ICC Family of Solutions

  • Privacy Policy
  • Terms of Use
  • Contact Us
  • Accessibility Policy
VVYTqUJQFhPhQRIBjOeigKASB3e_ImbIH1_wR5MBJ4M=.html