Hurricane and Typhoon Mitigation

Hurricanes, typhoons and nor'easters are among the most destructive and costly natural hazards affecting the United States and its territories. These powerful storms can cause extensive damage from high winds, heavy rainfall, storm surge, flooding and related impacts. While they typically develop over water and make landfall along coastal regions, their effects can extend hundreds of miles inland.

The effective application of modern building codes and standards plays a critical role in reducing damage, improving resilience and helping communities recover more quickly after these events.

How Often Hurricane Events Occur

Wind speeds associated with hurricanes, typhoons and nor'easters range from 74 mph to more than 157 mph, creating significant risks to buildings, infrastructure and communities. Areas most vulnerable to hurricanes, typhoons and nor'easters include the Atlantic, Pacific and Gulf coasts, Hawaii, U.S. Pacific territories and Caribbean territories.

According to the National Oceanic and Atmospheric Administration (NOAA), since the year 2000, the northern and southern hemispheres have experienced an average of 47 hurricanes and typhoons annually. Of those, the North Atlantic and Caribbean averaged seven hurricanes per year.

Hurricane-Related Losses

Hurricanes and typhoons are among the costliest single weather-related disasters in the U.S.

According to insurer Guardian Service, since 1980 hurricanes have caused over $1.5 trillion USD in damage, averaging $23 billion USD per hurricane across the U.S.

Hurricane Ian in 2022 alone resulted in an estimated $60 – $65 billion USD of insured losses, according to Karen Clark & Company.

Losses Avoided Through Building Codes and Mitigation

Modern building codes and hazard mitigation measures have proven to be some of the most effective tools for reducing hurricane and typhoon damage. By incorporating stronger wind-resistant design requirements, improved roofing and opening protection, enhanced connections between building components and flood-resistant construction practices, communities can significantly reduce property damage, business interruption and recovery costs.

A national benefit-cost analysis found adopting the latest building code requirements saves about $11 for every $1 invested.

FEMA's Building Codes Save: A Nationwide Study found that adoption of the International Codes® (I-Codes®) could help communities avoid between $132 billion USD and $171 billion USD in cumulative losses through 2040, and $600+ billion USD by 2060.

Overall, natural hazard mitigation saves up to $33 USD per $1 USD invested, depending on the hazard and mitigation measure.

Using the International Codes (I‑Codes) to Mitigate Hurricane Hazards

The International Codes® (I Codes®), including the 2024 International Building Code® (IBC), International Residential Code® (IRC) and International Existing Building Code® (IBC), provide a comprehensive framework for designing, constructing and retrofitting buildings to better withstand the effects of hurricanes. These codes establish minimum requirements that help protect life and property, reduce wind- and flood-related damage, and support faster community recovery following severe wind and flood events.

The 2024 I-Codes address five broad areas:

  • Hazard Identification and Design Criteria: Requirements for addressing hurricane-related hazards, including design wind speeds, flood hazards, storm surge risk, rainfall effects, exposure conditions and building risk categories used to establish design requirements
  • Structural Resistance and Load Path Continuity: Provisions that ensure buildings can resist and transfer hurricane forces safely through the structural system, including wind and flood loads acting on foundations, walls, roofs, connections and other structural elements
  • Building Envelope and Water Intrusion Protection: Requirements for roofs, exterior walls, openings, glazing, doors and other building components to resist wind pressures, wind-borne debris and wind-driven rain, helping reduce damage from envelope failures and water intrusion
  • Flood and Storm Surge Resilience: Provisions for siting, elevation, foundation design, flood-resistant construction and protection of building systems in areas subject to flooding, storm surge and coastal wave action
  • Protection of Critical Functions and Occupant Safety: Requirements that enhance life safety during hurricane events, including provisions for emergency egress, protection of critical building systems and where applicable, the design and construction of storm shelters and essential facilities

Key Hurricane Provisions

Click book cover below to reveal/hide code sections.

IBC icon

2024 IEBC cover

International Existing Building Code®

Chapter 1 Scope and Administration

Section 104 Duties and Powers of Code Official

  • 104.3.1 Determination of substantially improved or substantially damaged existing buildings and structures in flood hazard areas. For applications for reconstruction, rehabilitation, repair, alteration, addition or other improvement of existing buildings or structures located in flood hazard areas, the code official shall determine where the proposed work constitutes substantial improvement or repair of substantial damage. Where the code official determines that the proposed work constitutes substantial improvement or repair of substantial damage, the building is to meet the requirements of Section 1612 of the IBC, or Section R306 of the IRC, as applicable.

Section 106 Construction Documents

  • 106.2.4 Exterior wall envelope. Construction documents for work affecting the exterior wall envelope shall describe the exterior wall envelope in sufficient detail to determine compliance with this code. The construction documents shall include manufacturer’s installation instructions that provide supporting documentation regarding maintaining the wind and weather resistance of the exterior wall envelope.

Chapter 2 Definitions

Chapter 2 provides definitions for terms used throughout the IEBC. These definitions provide a common language for designing buildings to resist severe wind events. While the IEBC incorporates the definitions found in the IBC, those terms that are unique to existing buildings can be found within Chapter 2 of the IEBC.

Chapter 4 Repairs

Section 405 Structural

  • 405.2.3.1 Evaluation. Damaged buildings are to be evaluated by a registered design professional. The evaluation must establish whether the lateral force-resisting system of the damaged building, if repaired to its predamage state, would comply with the provisions of the IBC for load combinations that include wind effects.
  • 405.2.3.3 Extent of repair for noncompliant buildings. If the evaluation does not establish that the lateral force-resisting system of the building in its predamage condition complies with the provisions of Section 405.2.3.1, then the lateral force-resisting system is to be retrofitted.
  • 405.2.4.1 Lateral force-resisting elements. Regardless of the level of damage to vertical elements of the lateral force-resisting system, if substantial structural damage to gravity load-carrying components was caused primarily by wind, then the building is to be evaluated and, if noncompliant, it is to be retrofitted. There are a limited number of exceptions.

Chapter 5 Prescriptive Compliance Method

Section 502 Additions

  • 502.4 Existing structural elements carrying lateral load. When an addition to an existing building is not structurally independent, the lateral force-resisting system of the existing building and its addition acting together as a single structure shall comply with the IBC. There are a limited number of exceptions.

Section 503 Alterations

  • 503.4 Existing structural elements carrying lateral load. When an alteration to an existing building increases the design lateral loads, results in a prohibited structural irregularity as defined in ASCE 7 or decreases the capacity of any existing lateral load-carrying structural element, the lateral force-resisting system is required to meet the requirements of the IBC. There are a limited number of exceptions.
  • 503.12 Roof diaphragms resisting wind loads in high-wind regions. When an alteration to an existing building requires a permit for reroofing and involves removal of roofing materials from more than 50% of the roof diaphragm in areas where the basic wind speed is greater than 130 mph, the roof diaphragms and its connections are to be evaluated for the wind loads specified in the IBC. When diaphragms and connections are not capable of resisting 75% of those wind loads, they are to be replaced or strengthened.

Section 506 Change of Occupancy

  • 506.5.2 Snow and wind loads. Where a change of occupancy results in a building being assigned to a higher risk category, the building is required to satisfy the requirements of the IBC for the new risk category unless the area of the new occupancy is less than 10% of the building area.

Chapter 7 Alterations — Level 1

Section 706 Structural

  • 706.3.2 Roof diaphragms resisting wind loads in high-wind regions. When reroofing involves removal of roofing materials from more than 50% of the roof diaphragm in areas where the basic wind speed is greater than 130 mph, the roof diaphragms and its connections are to be evaluated for the wind loads specified in the IBC. When diaphragms and connections are not capable of resisting 75% of those wind loads, they are to be replaced or strengthened.

Chapter 8 Alterations — Level 2

Section 805 Structural

  • 805.3 Existing structural elements resisting lateral loads. When an alteration to an existing building increases the design lateral loads, results in a prohibited structural irregularity as defined in ASCE 7 or decreases the capacity of any existing lateral load-carrying structural element, the lateral force-resisting system is required to meet the requirements of the IBC. There are a limited number of exceptions.

Chapter 10 Change of Occupancy

Section 1006 Structural

  • 1006.2 Snow and wind loads.
    Where a change of occupancy results in a structure being assigned to a higher risk category, the structure is required to satisfy the requirements of the IBC for the new risk category unless the area of the new occupancy is less than 10% of the building area.

Chapter 11 Additions

Section 1103 Structural

  • 1103.2 Lateral force-resisting system. When an addition to an existing building is not structurally independent, the lateral force-resisting system of the existing building and its addition acting together as a single structure shall comply with the IBC. There are a limited number of exceptions. When calculating demand-capacity ratios for wind, the code wind forces in effect at the time are to be utilized.

Chapter 14 Relocated or Moved Buildings

Section 1402 Requirements

  • 1402.3 Wind loads. Relocated buildings are required to comply with IBC or IRC wind provisions, as applicable with only a few exceptions.

Chapter 15 Construction Safeguards

Section 1504 Protection of Pedestrians

  • 1504.1.7 Adjacent to excavations. Barriers are to be capable of resisting wind pressure as specified in the IBC.

Appendix C Guidelines for the Wind Retrofit of Existing Buildings

Appendix C is intended to provide prescriptive methods for structural retrofitting of existing buildings to increase their resistance to wind loads. It is intended for voluntary use where the basic wind speed, V, is greater than 130 mph. The provisions of this chapter do not necessarily satisfy requirements for new construction.

Read-Only Version of the IEBC

International Residential Code®

Chapter 2 Definitions

Chapter 2 provides definitions for terms used throughout the IRC. These definitions provide a common language for designing buildings to resist severe wind events. They help us understand wind hazard intensity, determine the forces buildings must withstand, and describe the structural systems and connections needed to create a continuous load path. Together, they ensure that buildings are designed with appropriate safety factors, sturdier connections and stronger performance in high-risk areas.

Chapter 3 Building Planning

Chapter 3 contains a wide array of building planning requirements that are critical to designing a safe and usable building. This includes but is not limited to general structural design as it relates to wind. Examples of wind-related provisions include:

Section R301 Design Criteria

  • R301.2.1 Wind design criteria Buildings and portions thereof shall be constructed in accordance with the wind provisions of the IRC using the ultimate design wind speeds provided. Additionally, where not otherwise specified, the wind loads provided are to be adjusted for height and exposure and are to be used to determine design load performance requirements for wall coverings, curtain walls, roof coverings, exterior windows, skylights, garage doors and exterior doors. The IRC also requires that a continuous load path be provided to transmit the applicable uplift forces from the roof assembly to the foundation.
  • R301.2.1.1 Wind limitations and wind design required The wind provisions of the IRC do not apply to the design of buildings where the ultimate design wind speed equals or exceeds 140 mph There are a limited number of exceptions.
  • R301.2.1.1.1 Sunrooms Sunrooms are required to comply with AAMA/NPEA/NSA 2100.
  • R301.2.1.2 Protection of openings Exterior glazing in buildings located in windborne debris regions are required to be protected from windborne debris. This is accomplished by requiring that glazed opening be protected from windborne debris by meeting the requirements of the Large Missile Test of ASTM E1886 and ASTM E1996. Garage door glazed opening protection for windborne debris is required to be of an approved impact-resisting standard or ANSI/DASMA 115. The only exception to this is if wood structural panels are employed. A fastening schedule for wood structural panels is provided in table format.
  • R301.2.1.3 Wind speed conversion The IRC provides a method of converting from nominal design wind speeds to ultimate design wind speeds in Table R301.2.1.3.
  • R301.2.1.4 Exposure category The IRC requires that buildings be designed by considering each direction the wind approaches from and its corresponding exposure category adequately reflecting the characteristics of ground surface irregularities. The IRC also requires that account be taken of variations in ground surface roughness that arise from natural topography and vegetation as well as from constructed features. For any given wind direction, the exposure in which a specific building or other structure is sited shall be assessed as being one of the following categories: Exposure B (Urban and suburban areas), Exposure C (Open terrain with scattered obstructions) or Exposure D (Flat, unobstructed areas).
  • R301.2.1.5 Topographic wind effects The IRC requires that areas having local historical data documenting structural damage to buildings caused by wind speed-up at isolated hills, ridges and escarpments are to be considered in the design of the building. In these designated areas, topographic wind effects shall apply only to buildings sited on the top half of an isolated hill, ridge or escarpment where the average slope of the top half of the hill, ridge or escarpment is 10% or greater and the hill, ridge or escarpment is 60 feet or greater in height for Exposure B, 30 feet or greater in height for Exposure C, and 15 feet or greater in height for Exposure D.
  • R301.2.2.7 Height limitations The IRC sets limitations on wood-framed buildings to three stories above grade plane. Cold-formed steel-framed buildings are limited to less than or equal to three stories above grade plane. Structural insulated panel buildings are limited to two stories above grade plane.

Section R307 Storm Shelters

  • R307.1 General This section applies to the design, construction and installation of storm shelters where constructed as either separate detached buildings or rooms or spaces within buildings for the purpose of providing protection from hurricanes and other severe windstorms.

Section R329 Solar Energy Systems

  • R329.4.1.2 Wind load Rooftop-mounted photovoltaic panel or module systems and their supports are to be designed and installed to resist specified component and cladding loads.

Chapter 4 Foundations

Chapter 4 provides requirements for constructing footings and walls for foundations of wood, masonry, concrete and precast concrete. Namely a foundation’s ability to support the required design loads including the effects from wind loads. Examples of wind-related provisions include:

Section R404 Foundation and Retaining Walls

  • R404.5.2 Precast concrete foundation design drawings The IRC requires that precast concrete foundation wall design drawings shall be submitted to the building official and approved prior to installation. These drawings are to include, at a minimum, the following information:
    1. Design loading as applicable.
    2. Footing design and material.
    3. Concentrated loads and their points of application.
    4. Soil bearing capacity.
    5. Maximum allowable total uniform load.
    6. Seismic design category.
    7. Basic wind speed.

Chapter 5 Floors

Chapter 5 provides the requirements for the design and construction of floor systems that will be capable of supporting minimum required design loads. Namely a floor’s ability to support the required design loads including the effects from wind loads. This chapter covers wood floor framing, wood floors on the ground and cold-formed steel floor framing. Examples of wind-related provisions include:

Section R502 Wood Floor Framing

  • R502.12.4 Truss design drawings The IRC requires that truss design drawings are to be submitted to the building official and approved prior to installation. It also requires that the truss design drawings be provided with the shipment of trusses delivered to the job site and include, at a minimum, the following information:
    1. Slope or depth, span and spacing.
    2. Location of all joints.
    3. Required bearing widths.
    4. Design loads as applicable:
      • 4.1. Top chord live load.
        4.2. Top chord dead load.
        4.3. Bottom chord live load.
        4.4. Bottom chord dead load.
        4.5. Concentrated loads and their points of application.
        4.6. Controlling wind and earthquake loads.

Section R505 Cold-Formed Steel Floor Framing

  • R505.1.1 Applicability limits The IRC provides provisions that control the construction of cold-formed steel floor framing for buildings and limits them to not greater than 60 feet in length perpendicular to the joist span, not greater than 40 feet in width parallel to the joist span and less than or equal to three stories above grade plane. Additionally, cold-formed steel floor framing is limited to sites where the ultimate design wind speed is less than 140 mph Exposure Category B or C.
  • TABLE R505.3.1(1) The IRC also provides floor-to-foundation or bearing wall connection requirements in tabular form in TABLE R505.3.1(1).

Chapter 6 Wall Construction

Chapter 6 contains prescriptive provisions for the design and construction of walls. Namely a wall’s ability to support the required design loads including the effects from wind loads. The wall construction covered in Chapter 6 consists of five different types: wood framed, cold-formed steel framed, masonry, concrete and structural insulated panel (SIP). This chapter covers wood floor framing, wood floors on the ground and cold-formed steel floor framing. Examples of wind-related provisions include:

Section R602 Wood Wall Framing

  • R602.3 Design and construction The IRC requires exterior walls of wood-frame construction to be designed and constructed in accordance with the prescriptive provisions of this chapter or in accordance with AWC NDS. It also requires that components of exterior walls and wall sheathing are to be fastened directly to framing members and, where placed on the exterior side of an exterior wall, to be capable of resisting the wind pressures.

These prescriptive requirements are listed in tabular format in TABLE R602.3(3) titled Requirements for Wood Structural Panel Wall Sheathing Used to Resist Wind Pressures.

  • R602.3.5 Braced wall panel uplift load path The IRC requires that exterior wall panels that support roof rafters or trusses (including stories below top story) to have the framing members connected to resist gravity and wind uplift loads. These prescriptive requirements are listed in tabular format in the following tables:
    • TABLE R602.10.3(1) BRACING REQUIREMENTS BASED ON WIND SPEED
    • TABLE R602.10.6.4 TENSION STRAP CAPACITY FOR RESISTING WIND PRESSURES PERPENDICULAR TO METHODS PFH, PFG AND CS-PF BRACED WALL PANELS

Section R603 Cold-Formed Steel Wall Framing

The IRC provides prescriptive requirements regarding the use of cold-formed steel wall framing. The specific provisions can be found in the following tables:

  • TABLE R603.3.1 WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTS
  • TABLE R603.3.1.1(1) GABLE ENDWALL TO FLOOR CONNECTION REQUIREMENTS
  • TABLE R603.3.2(1 - 16) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
  • TABLE R603.3.2.1(1 - 2) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHT
  • TABLE R603.7(1 - 2) HEADER TO KING STUD CONNECTION REQUIREMENTS
  • TABLE R603.8 HEAD AND SILL TRACK SPAN
  • R603.9.4.1 Ultimate design wind speeds greater than 130 mph. The IRC also sets out additional limitations on these walls by specifying that when the ultimate design wind speeds exceed 130 mph for Exposure Category C, the walls are to be provided with direct uplift connections.

Section R606 General Masonry Construction

  • R606.4.4 Parapet walls The IRC provides prescriptive requirements on unreinforced solid masonry parapet walls that are not less than 8 inches thick, and their height is not to exceed four times their thickness. Similarly, unreinforced hollow unit masonry parapet walls are to be not less than 8 inches thick, and their height shall not exceed three times their thickness.

Section R607 Glass Unit Masonry

  • R607.4.1 Exterior standard-unit panels The IRC establishes a maximum area of each individual standard-unit glass masonry panel of 144 square feet where the design wind pressure is 20 pounds per square. It also sets the maximum panel dimension between structural supports at 25 feet in width or 20 feet in height.

Section R608 Exterior Concrete Wall Construction

  • R608.2 Applicability limits The prescriptive provisions of this section apply to the construction of exterior concrete walls for buildings not greater than 60 feet in plan dimensions, floors with clear spans not greater than 32 feet and roofs with clear spans not greater than 40 feet and Buildings not exceeding 35 feet in mean roof height or two stories in height above grade. Additionally, walls constructed in accordance with the provisions of this section are limited to a maximum design wind speed of 160 mph Exposure B, 136 mph Exposure C and 125 mph Exposure D.
  • R608.6.2 Wall reinforcement for wind The prescriptive requirements of this section state that vertical wall reinforcement for resistance to out-of-plane wind forces is to be determined using Tables R608.6(1), R608.6(2), R608.6(3) or R608.6(4). For the design of nonload-bearing walls, Tables R608.6(1), R608.6(2) and R608.6(3) are to be used.

Additionally, there are to be a vertical bars at corners of exterior walls with a minimum horizontal reinforcement of four No. 4 bars [Grade 40 (280 MPa)] placed as follows: top bar within 12 inches (305 mm) of the top of the wall, bottom bar within 12 inches (305 mm) of the finish floor and one bar each at approximately one-third and two-thirds of the wall height.

Section R609 Exterior Windows and Doors

  • R609.2 Performance The IRC requires that exterior windows and doors are to be capable of resisting design wind loads adjusted for height and exposure.
  • R609.4.1 Garage door labeling Garage doors are to be labeled with a permanent label provided by the garage door manufacturer that identifies the garage door manufacturer, the garage door model/series number, the positive and negative design wind pressure rating, the installation instruction drawing reference number and the applicable test standard.
  • R609.6 Windborne debris protection. The IRC requires that all exterior windows, glass doors and doors with glass in buildings located in windborne debris regions are to be protected against windborne debris.

Chapter 7 Wall Covering

Chapter 7 establishes the various types of materials, materials standards and methods of application permitted as interior and exterior wall coverings. Exterior wall coverings regulated by this section include aluminum, stone and masonry veneer, wood, hardboard, particleboard, wood structural panel siding, wood shakes and shingles, exterior plaster, steel, vinyl, fiber cement and exterior insulation finish systems. This chapter also contains requirements relating to wind resistance for exterior wall coverings. Examples of wind-related provisions include:

Section R703 Exterior wall Covering

  • R703.1.2 Wind resistance The IRC requires that exterior wall coverings, siding, exterior soffit and backing materials and their attachments are to be capable of resisting wind loads.
  • R703.3.2 Wind limitations Among the limitations for the IRC’s prescriptive requirements, when the design wind pressure exceeds 30 psf, the attachment of wall coverings is to be designed to resist component and cladding loads for walls and adjusted for height and exposure. The prescriptive attachment requirements are tabularized into TABLE R703.11.2 title Required Minimum Wind Load Design Pressure Rating for Vinyl Siding Installed Over Foam Plastic Sheathing Alone.

Section R703 Exterior wall Covering

  • R704.1 General wind limitations Among the IRC’s limitations, when the design wind pressure exceeds 30 psf, the attachment of exterior soffits is to comply with the design wind pressure determined using the component and cladding loads for walls using an effective wind area of 10 square feet and adjusted for height and exposure.
  • R704.3.1 Vinyl exterior soffit panels When the exterior soffit panels are vinyl, their attachments are to be capable of resisting wind loads for walls using an effective wind area of 10 square feet and adjusted for height and exposure and installed using fasteners specified by the manufacturer. They are also to be fastened at both ends to a supporting component such as a nailing strip, fascia or subfascia component. Where the unsupported span of exterior soffit panels is greater than 12 inches, intermediate nailing strips are to be provided.
  • R704.3.2 Fiber-cement exterior soffit panels. When the exterior soffit panels are Fiber-cement, their attachments are to be capable of resisting wind loads for walls using an effective wind area of 10 square feet and adjusted for height and exposure and installed using fasteners specified by the manufacturer.
  • R704.3.3 Hardboard exterior soffit panels. When the exterior soffit panels are Hardboard, their attachments are to be capable of resisting wind loads for walls using an effective wind area of 10 square feet and adjusted for height and exposure and installed using fasteners specified by the manufacturer.
  • R704.3.4 Wood structural panel exterior soffit. When the exterior soffit panels are structural wood, their attachments are to be capable of resisting wind loads for walls using an effective wind area of 10 square feet and adjusted for height and exposure and installed using fasteners specified by the manufacturer.

Chapter 8 Roof-Ceiling Construction

Chapter 8 addresses the design and construction of roof-ceiling systems. This chapter contains two roof-ceiling framing systems: wood framing and cold-formed steel framing. This chapter also contains requirements relating to wind resistance for these systems. Examples of wind-related provisions include:

Section R802 Wood Roof Framing

  • R802.10.1 Truss design drawings. The IRC requires that truss design drawings are to be submitted to the building official and approved prior to installation. It also requires that the truss design drawings be provided with the shipment of trusses delivered to the job site and include, at a minimum, the following information:
    1. Slope or depth, span and spacing.
    2. Location of all joints.
    3. Required bearing widths.
    4. Design loads as applicable:
      • 4.1. Top chord live load.
        4.2. Top chord dead load.
        4.3. Bottom chord live load.
        4.4. Bottom chord dead load.
        4.5. Concentrated loads and their points of application.
  • R802.10.2.1 Applicability limits The IRC provides provisions that control the construction of wood roof framing for buildings and limits them to not greater than 60 feet in length perpendicular to the joist span, not greater than 36 feet in width parallel to the joist span and less than or equal to three stories above grade plane. Additionally, wood roof framing is limited to sites where the ultimate design wind speed is less than 140 mph Exposure Category B or C.
  • R802.11 Roof tie uplift resistance The IRC requires that roof assemblies be provided with uplift resistance based on the design wind loads. Exceptions include rafters or trusses that are attached to their supporting wall assemblies where the uplift force per rafter or truss does not exceed 200 pounds or where the basic wind speed does not exceed 115 mph for exposure category B and the roof pitch is 5 units vertical in 12 units horizontal or greater. The values for rafter or truss uplift connection forces from wind can be found in TABLE R802.11.
  • R802.11.1 Truss uplift resistance The IRC requires that roof trusses be attached to supporting wall assemblies by connections capable of resisting uplift forces as specified on the truss design drawings for the ultimate design wind speed.

Section R804 Cold-Formed Steel Roof Framing

  • R804.1.1 Applicability limits. The IRC provides provisions that control the construction of cold-formed steel roof framing for buildings and limits them to not greater than 60 feet in length perpendicular to the joist span, not greater than 40 feet in width parallel to the joist span and less than or equal to three stories above grade plane. Additionally, cold-formed steel roof framing is limited to sites where the ultimate design wind speed is less than 140 mph for Exposure Category B or C. Roof framing fastening schedules can be found in TABLE R804.3.

Chapter 9 Roof Assemblies

Chapter 9 addresses the design and construction of roof assemblies. A roof assembly includes the roof deck, substrate or thermal barrier, insulation, vapor retarder and roof covering. Among other requirements, this chapter identifies the requirement for wind resistance of roof coverings. The types of roof covering materials and installation addressed by Chapter 9 are: asphalt shingles, clay and concrete tile, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shakes and shingles, built-up roofs, metal roof panels, modified bitumen roofing, thermoset and thermoplastic single-ply roofing, sprayed polyurethane foam roofing, liquid applied coatings and building-integrated photovoltaic (BIPV) roof coverings. Examples of wind-related provisions include:

Section R905 Requirements for Roof Coverings

The IRC specifies requirements for roof underpayments in the following tables:

  • TABLE R905.1.1(1) UNDERLAYMENT TYPES
  • TABLE R905.1.1(2) UNDERLAYMENT APPLICATION
  • TABLE R905.1.1(3) UNDERLAYMENT ATTACHMENT
  • R905.2.4.1 Wind resistance of asphalt shingles. The IRC requires that asphalt shingles shall be tested in accordance with ASTM D7158and that they meet specific classification requirements relating to the appropriate ultimate design wind speed. The IRC also requires that asphalt shingle packaging bears a label to indicate compliance with ASTM D7158.
  • R905.3.6 Wind resistance of concrete and clay tile. In regions where wind design is required the IRC requires that wind loads on concrete and clay tile are to be determined.
  • R905.4.4.1 Wind resistance of metal roof shingles. The IRC requires that metal roof shingles fastened to wood structural panels, solid lumber sheathing or closely fitted lumber sheathing are to be tested in accordance with ASTM D3161, FM 4474, UL 580 or UL 1897 for the appropriate maximum basic wind speed. Additionally, metal shingle packaging is to bear a label indicating compliance with ASTM D3161.
  • R905.5.6 Wind resistance of mineral-surfaced roll roofing. The IRC requires that mineral-surfaced roll roofing shall be installed to resist the component and cladding wind loads adjusted for height and exposure.
  • R905.6.5 Wind resistance of slate shingles. The IRC requires that slate shingles are to be tested in accordance with ASTM D3161 and its packaging is to bear a label indicating compliance with ASTM D3161.
  • R905.7.5 Wind resistance of wood shingles. In regions where wind design is required the IRC requires that wood shingles are to be installed to resist the component and cladding wind loads and adjusted for height and exposure.
  • R905.8.6 Wind resistance of wood shakes. In regions where wind design is required the IRC requires that wood shakes are to be installed to resist the component and cladding wind loads and adjusted for height and exposure.
  • R905.9.4 Wind resistance of built-up roofs. In regions where wind design is required the IRC requires that Built-up roof coverings are to be installed to resist the component and cladding wind loads and adjusted for height and exposure.
  • R905.10.5 Wind resistance of metal roof panels. In regions where wind design is required the IRC requires that metal roof panels are to be installed to resist the component and cladding wind loads and adjusted for height and exposure. In cases where metal roof panels are applied to a solid or closely fitted deck they are to be tested for wind resistance as appropriate and with a limited number of exceptions.
  • R905.11.4 Wind resistance of modified bitumen roofing. In regions where wind design is required the IRC requires that Modified bitumen roofing is to be installed to resist the component and cladding wind loads and adjusted for height and exposure.
  • R905.12.4 Wind resistance of single-ply roofing.
    In regions where wind design is required the IRC requires that Single-ply roofing is to be installed to resist the component and cladding wind loads and adjusted for height and exposure.
  • R905.13.4 Wind resistance of sprayed polyurethane foam roofing. In regions where wind design is required the IRC requires that Sprayed polyurethane foam roofing is to be installed to resist the component and cladding wind loads and adjusted for height and exposure.
  • R905.14.4 Wind resistance of liquid-applied roofing. In regions where wind design is required the IRC requires that Liquid-applied roofing is to be installed to resist the component and cladding wind loads and adjusted for height and exposure.

Read-Only Version of the IRC

International Building Code®

Chapter 2 Definitions

Chapter 2 provides definitions for terms used throughout the IBC. These definitions provide a common language for designing buildings to resist severe wind events. They help us understand wind hazard intensity, determine the forces buildings must withstand and describe the structural systems and connections needed to create a continuous load path. Together, they ensure that buildings are designed with appropriate safety factors, sturdier connections and stronger performance in high-risk areas.

Chapter 4 Special Detailed Requirements Based on Occupancy and Use

Section 423 Storm Shelters: This entire section applies to the design and construction of storm shelters constructed as separate detached buildings or constructed as rooms or spaces within buildings for the purpose of providing protection from tornadoes, hurricanes and other severe windstorms during the storm. This section specifies where storm shelters are required and provides requirements for the design and construction of storm shelters.

  • 423.2 Construction – storm shelters are to be constructed in accordance with this code and ICC 500 and shall be designated as hurricane shelters, tornado shelters or combined hurricane and tornado shelters.
  • 423.3 Occupancy classification – occupancy classifications for storm shelters are determined based on whether the shelter is a dedicated storm shelter, a storm shelter within a host building, its design occupancy load and its location relative the building(s) it services.

Chapter 9 Fire Protection and Life Safety Systems

Section 909 Smoke Control Systems

  • 909.4.1 Smoke control – stack effect. Smoke control system is designed so normal or reverse stack effect doesn't interfere is the system's capabilities.
  • 909.4.3 Smoke control – wind effect. Smoke control system design considers adverse wind effects.
  • 909.20.4 Smoke control - stairway and ramp pressurization. Pressurization relative to stairway and ramp

Section 913 Fire Pumps

  • 913.2 Fire pumps – interruption of service. Protection of fire pump, driver and controller against service interruption through damage caused by windstorm, flood and other special weather and environmental conditions.

Chapter 10 Means of Egress

Section 1031 Emergency Escape and Rescue

  • 1031.2 Where required – storm shelter exception. Storm shelters are excepted to include emergency escape and rescue openings.

Chapter 11 Accessibility

Section 1112 Signage

  • 1112.5.2 Variable message signs – emergency shelters. Emergency shelters must provide variable message signage conveying emergency-related information.

Chapter 14 Exterior Walls

Section 1402 Performance Requirements

  • 1402.3 Performance requirements - wind resistance. Exterior walls and coverings, soffits and associated openings designed to resist superimposed loads.

Section 1404 Installation of Wall Coverings

  • 1404.12.1 Attachment. Exterior metal veneer attachment fastenings and their spacing designed to resist wind loads specified in Section 1609.
  • 1404.15 Vinyl siding and insulated vinyl siding - design wind pressure requirements. Vinyl siding permitted on exterior walls where the design wind pressure does not exceed 30 psf., or else compliance with Chapter 16.
  • 1404.15.2 Installation over foam plastic insulated sheathing - design pressure requirements. Vinyl siding over foam plastic sheathing to comply with Section 1404.15 and have wind load design pressure rating in accordance with Table 1404.15.2.
  • 1404.17 Fiber cement siding. Fiber-cement siding permitted on exterior walls for wind pressure resistance or basic wind speed exposures as indicated by the manufacturer's listing and installation instructions.
  • 1404.18 Polypropylene siding. Polypropylene siding is limited to exterior walls in areas meeting maximum basic wind speeds specified in Chapter 16, with building height considerations.

Section 1406 Metal Composite Material (MCM)

  • 1406.4 Structural design. Metal composite materials designed and constructed to resist wind loads as required by Chapter 16 for components and cladding.
  • 1406.5 Approval. Results of approved tests or engineering analysis to be submitted to the building official for compliance verification with Chapter 16 for wind loads.
  • 1406.6 Weather resistance. MCM systems must be designed and constructed to resist wind and rain in accordance with this section and manufacturer's installation instructions.

Section 1407 Exterior Insulation and Finish Systems (EIFS)

  • 1407.3 Structural design. Underlying structural framing and substrate to be designed and constructed to resist loads as required by Chapter 16.
  • 1407.4 Weather resistance. System designed and constructed to resist wind and rain in accordance with this section and manufacturer's application instructions.

Section 1408 High-Pressure Decorative Exterior-Grade Compact Laminates (HPL)

  • 11408.4 Structural design. HPL system to be designed and constructed to resist wind loads as required by Chapter 16 for components and cladding.
  • 1408.5 Approval. Results of approved tests or engineering analysis to be submitted to the building official for compliance verification with Chapter 16 for wind loads.
  • 1408.6 Weather resistance. HPL systems must be designed and constructed to resist wind and rain in accordance with this section and manufacturer's installation instructions.

Section 1409 Insulated Metal Panel (IMP)

  • 1409.2 Structural design. Structural design of IMP system to be in accordance with this section.
  • 1409.3 Weather resistance. IMP systems must be designed and constructed to resist wind and rain in accordance with this section and manufacturer's installation instructions

Section 1412 Soffits and Fascias at Roof Overhangs

  • 1412.2 General wind requirements. Soffits and fascias capable of resisting components and cladding loads for walls in accordance with Chapter 16 using an effective wind area of 10 square feet.
  • 1412.3 Vinyl & aluminum soffit panels. Vinyl and aluminum soffit panels to meet fastener and installation instruction requirements based on required design wind pressures.
  • 1412.5 Hardboard soffit panels. Hardboard soffit panel minimum thickness and installation instruction requirements to meet required design wind pressures.
  • 1412.7 Aluminum fascia. Aluminum fascia to meet minimum thickness and manufacturer's installation instruction requirements.

Chapter 15 Roof Assemblies and Rooftop Structures

Section 1504 Performance Requirements

  • 1504.1 Wind resistance of roofs. Roof decks and roof coverings to be designed in accordance with Section 1504.
  • 1504.2 Wind resistance of asphalt shingles. Asphalt shingles tested to ASTM D7158 and meet classification requirements of Table 1504.2 for maximum basic wind speed.
  • 1504.3 Wind resistance of clay and concrete tile. Wind loads on clay and concrete tile roof coverings to be in accordance with Section 1609.6.
  • 1504.4 Wind resistance of nonballasted roofs (includes built-up, modified bitumen, fully adhered/mechanically attached, metal shingles, metal panels, and slate). Roof coverings mechanically attached to the roof deck to be designed to resist design wind load pressures with Section 1609.6.2.
  • 1504.5 Ballasted low-slope single-ply roof systems. Ballasted low-slope single-ply roof system coverings to be installed in accordance with Section 1507.12 and designed to ANSI/SPRI RP-4.
  • 1504.6 Edge systems for low-slope roofs. Metal edge systems installed on specific low-slope roof systems to be designed and installed for wind loads to Chapter 16 and certain test standards.
  • 1504.8 Wind resistance of aggregate-surfaced roofs – parapets. Parapets provided for aggregate surfaced roofs and comply with Table 1504.8 and include installation location requirements.

Section 1507 Requirements for Roof Coverings

  • 1507.1.1 Underlayment. Underlayment requirements based on roof covering materials through this section and 3 associated Table 1507.1.1 tables.
  • 1507.3.7 Clay and concrete tile attachment. Clay and concrete roof tiles to be fastened in accordance with Table 1507.3.7.
  • 1507.16.8 Building Integrated Photo Voltaic (BIPV) shingles - wind resistance. Shingles to comply with requirements of Table 1504.2 for the appropriate maximum basic wind speed.
  • 1507.17.4 Building Integrated Photo Voltaic (BIPV) panels – underlayment. Addresses underlayment application method and 1507.4.1 further addresses high-wind attachment requirements.

Chapter 16 Structural Design

Section 1602 Notations

  • 1602.1 Notations (abbreviations). Chapter notations defined.

Section 1603 Construction Documents

  • 1603.1.4 Wind design data. Construction documents for wind design data.

Section 1604 General Design Requirements

  • 1604.3 Serviceability . General design requirements for structural systems and members.
  • 1604.5 Risk category. Building risk category is established based on Table 1604.5
  • 1604.8 Anchorage. Buildings must have anchorage in accordance with Sections 1608.1 through 1604.8.3.
  • 1604.9 Wind and seismic detailing. Lateral force-resisting systems to meet seismic detailing requirements where wind load effects are greater than seismic load effects.
  • 1604.10. Loads on storm shelters. Loads and load combinations on storm shelters to be determined in accordance with ICC 500.

Section 1605 Load Combinations: Requirements in this section address a building's strength load combinations.

Section 1609 Wind Loads: Requirements in this section address a building's minimum wind load designs.

Section 1612 Flood Loads

  • 1612.4 Flood hazard documentation. Outlines design documentation criteria for construction in coastal high hazard and coastal A zones.

Chapter 17 Special Inspections and Tests

Section 1704 Special Inspections and Tests, Contractor Responsibility and Structural Observation

  • 1704.3.3 Statement of special inspections – wind requirements. Statement identifying the designated seismic and seismic force-resisting systems subject to special inspections or tests.

Section 1705 Required Special Inspections and Tests

  • 1705.12 Special inspections for wind resistance. Required wind exposure categories where special inspections for wind resistance is required.

Section 1709 Preconstruction Load Tests

  • 1709.5 . Exterior window and door assemblies – wind pressure requirements. Pre-construction load tests - design pressure rating requirements for exterior windows and doors.

Chapter 18 Soils and Foundations

Section 1806 Presumptive Load-Bearing Values of Soils

  • 1806.1 Presumptive load-bearing values of soils - load combinations. Requirements for load-bearing values used with the allowable stress design load combinations

Section 1810 Deep Foundations

  • 1810.3.2.6 Design and detailing – materials – allowable stresses. Maximum allowable stresses for materials used in deep foundations as listed in Table 1810.3.2.6.
  • 1810.3.3.1.5 Design and detailing – determination of allowable loads – allowable axial load – uplift capacity of single deep foundation element. Uplift capacity of a single deep foundation element to be determined by an approved method of analysis

Chapter 21 Masonry

Section 2109 Empirical Design of Adobe Masonry

  • 2109.1.1 Empirical design of Adobe masonry – limitations. Adobe masonry design limitations based on specified Sections in this code, TMS 402-16 modification for wind

Chapter 23 Wood

Section 2304 General Construction Requirements

  • 2304.6 Exterior wall sheathing. Wood products used as exterior wall sheathing and their connections must be designed and installed according to the maximum basic wind speed and wind pressures in this section.

Section 2305 General Design Requirements for Lateral Force-Resisting Systems: Lateral force-resisting systems using wood products in shear walls and diaphragms must meet the design requirements of this section.

Section 2306 Allowable Stress Design: This section addresses allowable stress designs for a variety of wood products and applications.

Section 2307 Load and Resistance Factor Design: When using load and resistance factor design, wood elements and structures must meet the requirements of ANSI/AWC NDS and AWC SDPWS.

Section 2308 Conventional Light-Frame Construction

  • 2308.2 Limitations. Buildings of light-frame construction must be designed and constructed in accordance with the wind and load requirements of this section which include provisions for tornado loads and hurricane-prone regions.
  • 2308.11.4 Roof and ceiling framing. Roof construction must be attached to the wall below with connections capable of resisting the required uplift loads according to the table or the truss design drawings.

Chapter 24 Glass and Glazing

Section 2404 Wind, Snow, Seismic and Dead Loads on Glass

  • 2404.1 Vertical glass. Vertical glass (sloped 15 degrees or less from vertical) in exterior applications must be designed to resist wind loads in accordance with the requirements in section 1609.
  • 2404.2 Sloped glass. Glass sloped more than 15 degrees from vertical in exterior applications must be designed to resist the most critical load combination determined by the equations in this section.
  • 2404.3 Wired, patterned, and sandblasted glass (vertical and sloped). Wired, patterned and sandblasted glass, both vertical and sloped, in exterior applications must be designed to resist wind loads according to section 1609 and the equations in this section.

Chapter 25 Gypsum Panel Products and Plaster

Section 2505 Shear Wall Construction: Gypsum panel products and plasters used in shear wall assemblies must comply with this section.

Section 2508 Gypsum Construction

  • 2508.6 Horizontal gypsum panel product diaphragm ceilings. Gypsum panel products used in horizontal diaphragm ceilings must meet the requirements of this section.

Chapter 26 Plastic

Section 2603 Foam Plastic Insulation

  • 2603.10 Wind resistance. Foam plastic insulation used as sheathing must comply with wind resistance required by ANSI/SBCA FS 100.

Chapter 30 Elevators and Conveying Systems

Section 3001 General

  • 3001.6 Structural design. Elevators, escalators and other conveying systems must be designed according to the applicable wind load requirements of section 1609.

Chapter 31 Special Construction

Section 3102 Membrane Structures

  • 3102.7 Engineering design. Membrane structures must be designed to sustain a variety of loads, including the wind loads specified in Chapter 16.

Section 3103 Temporary Structures

  • 3103.6.1.2 Structural requirements – structural loads – wind loads. Design wind loads for public-occupancy temporary structures, like tents and bleachers, may be reduced by the factors listed in this section and the accompanying table.
  • 3103.8 Controlled occupancy procedures. Where controlled occupancy procedures are required for a public-occupancy temporary structure, wind speeds must be monitored before and during occupancy, and the structure must be vacated if the design wind speed is expected to be exceeded.

Section 3105 Awnings and Canopies

  • 3105.2 Design and construction. Awnings and canopies must be designed to handle wind loads as required in Chapter 16.

Section 3111 Solar Energy Systems

  • 3111.1.1 General - wind resistance. Roof-mounted photovoltaic systems and solar thermal collectors must be designed according to section 1609.

Section 3113 Relocatable Buildings

  • 3113.2 Supplemental information. Information submitted to the AHJ for relocatable buildings must include the design loads specified in this section.
  • 3113.3 Manufacturer's data plate. The manufacturer's data plate on relocatable buildings must include the design loads specified in this section.

Section 3114 Intermodal Shipping Containers

  • 3114.8 Structural. Intermodal shipping containers that conform to ISO 1496-1 to be used as buildings or structures must be designed to meet Chapter 16 and this section.

Chapter 33 Safeguards During Construction

Section 3306

  • 3306.9 Adjacent to excavations. Barriers adjacent to excavation sites must be designed to resist wind pressures specified in Chapter 16.

Read-Only Version of the IBC

Hurricane Resources

Preparedness

Emergency Planning

Visit Ready.gov for emergency planning, evacuation preparation, alerts and household readiness resources for hurricanes.

Training for Officials

When Disaster Strikes Institute’s Disaster Planning for the Building Department course outlines roles, responsibilities and readiness strategies before hurricane-related disasters.

Response

Stay Safe

Learn how to stay safe during and after a wind event. Follow evacuation orders, avoid debris and flooded areas and stay informed through local emergency alerts.

Training for Officials

When Disaster Strikes Institute’s Evaluator and Coordinator Training courses teach professionals how to safely assess post event structures and determine habitability.

Recovery

Damage Assessment

Damage assessments help determine structural integrity, identify hazardous conditions and guide decisions about repair, demolition or rebuilding. Updated 2024 I Codes include clarified definitions and documentation requirements to support efficient recovery and consistent enforcement.

Pairing Mitigation with Local Recovery

When communities begin recovering after a severe hurricane event, it’s essential to rebuild with future resilience in mind. Local governmental leaders, recovery committees and planning groups can integrate mitigation into every recovery decision by using established assessment methods, such as state and local hazard mitigation plans and applying a multi-hazard approach to rebuilding.

Use hazard mitigation plans as roadmaps

Reference state or local hazard mitigation plans to guide decisions on where and how recovery projects should be designed, funded and implemented.

Conduct post‑event damage & risk assessments

Evaluate the extent of damage, identify recurring problem areas and document vulnerabilities to inform mitigation‑focused rebuilding.

Embed mitigation in all recovery discussions

Ensure that community town hall meetings, planning meetings and community workshops include mitigation options as part of every proposed solution.

Prioritize multi‑hazard strategies

Consider community hazards and risks beyond hurricane events (e.g. flooding, wildfire, earthquakes, etc.) and pursue solutions that reduce exposure to multiple hazards at once.

Leverage recovery funding for mitigation

Explore opportunities within federal, state and local disaster assistance funding programs that allow or encourage mitigation as part of repair and reconstruction.

Rebuild with resilience

Encourage use of hurricane-resistant materials and installation methods and infrastructure designs that address long‑term risk.

Engage the community

Involve residents, businesses and local organizations to ensure mitigation measures reflect community needs and support long‑term resilience.