Skip to Main Content

Snow Mitigation

Snow and winter storms are common hazards across much of the United States. Heavy snow, drifting snow, ice buildup and rain-on-snow events can damage homes, businesses and critical facilities, disrupt roads, utilities and emergency services, and, in severe cases, contribute to roof failures or structural collapse.

Because snow hazards vary by region, communities benefit from using local climate data, current codes and practical mitigation strategies to reduce risk before storms occur.

How Often Snow Events Occur

Snow and winter storms affect communities across much of the United States every year. Records from the National Oceanic and Atmospheric Administration (NOAA) document thousands of winter weather events – including heavy snow, blizzards and winter storms – most common in regions like the Rocky Mountains, Great Plains, Great Lakes, Northeast and Alaska.

Snow-Related Losses

In many snow-prone areas, communities may face several significant events in one season. These storms can close roads, interrupt utilities and emergency services, damage buildings and create life-safety risks. The most severe events also carry major economic costs: NOAA’s Billion-Dollar Weather and Climate Disasters database reports 24 U.S. winter storm disasters from 1980 through 2024 that each caused more than $1 billion in damage, totaling more than $104 billion in losses.

Losses Avoided Through Building Codes and Mitigation

Adopting and enforcing up-to-date building codes is one of the most effective ways communities can reduce long-term losses from snow and winter storms. Strong codes help buildings better withstand snow loads, ice buildup and related winter conditions, which can reduce structural damage, service disruptions and recovery costs.

For snow-related hazards, modern codes address issues such as roof snow loads, drifting snow, rain-on-snow conditions, ice dams and roof drainage. These provisions give code officials, designers, builders and property owners a practical basis for reducing roof overload, structural damage and winter-related service disruptions.

FEMA estimates hazard-resistant codes save about $1.6 billion annually and could avoid nearly $133 billion in cumulative losses from 2000 to 2040.

The National Institute of Building Sciences found that current code requirements save $11 for every $1 invested, while adding about 1 percent to construction costs.

FEMA found federally funded mitigation grants save $6 for every $1 invested by reducing property damage, displacement, business interruption and recovery expenses.

Using the International Codes (I‑Codes) to Mitigate Snow Hazards

The International Codes® (I-Codes) help communities design, build, repair and retrofit buildings so they are better prepared for snow-related hazards. By adopting and applying nationally recognized codes and standards – including the International Building Code® (IBC), International Residential Code® (IRC), International Existing Building Code® (IEBC) and ASCE 7 – communities can address risks from heavy snow accumulation, drifting snow, ice loading and other winter storm conditions.

Key Snow Provisions in the I-Codes

Click book cover below to reveal/hide code sections.

IBC icon

2024 IEBC cover

International Existing Building Code®

Chapter 2: Definitions

These definitions provide a common language for evaluating and repairing existing buildings affected by snow-related hazards. While the IEBC incorporates the definitions found in the International Building Code® (IBC), terms that are unique to existing buildings can be found within Chapter 2 of the IEBC.

Chapter 3 Provisions for All Compliance Methods

Chapter 3 explains the three compliance options which include repairs from extreme weather events including ice are to comply with the provisions of Chapter 4.

  • 304.2 Snow loads on adjacent buildings. This section specifies that where an alteration or addition changes the potential snow drift effects on an adjacent building, the code official is authorized to enforce Sections within ASCE 7.

Chapter 4 Repairs

Chapter 4 provides requirements for repairs of existing buildings. The provisions within this chapter define conditions under which repairs may be made using materials and methods like those of the original construction or the extent to which repairs must comply with requirements for new buildings.

  • 4405.2.1.1 Snow damage. This section establishes the requirement that any structural components whose damage was caused by or related to snow load effects is to be repaired, replaced or altered to satisfy the requirements of the IBC.
  • 405.2.4 Substantial structural damage to gravity load-carrying components. This section establishes the requirement that any gravity load-carrying components that have sustained substantial structural damage shall be retrofitted to comply with the applicable provisions for dead, live and snow loads in the IBC. It also requires that undamaged gravity load-carrying components that receive dead, live or snow loads from retrofitted components shall also be retrofitted as required.
  • 405.2.5 Substantial structural damage to snow load-carrying components. This section requires that substantial structural damage caused by or related to snow load effects to any snow load-carrying components is to be repaired, replaced or retrofitted to satisfy the requirements of the IBC.

Chapter 7 Alterations—Level 1

Chapter 7 provides the technical requirements for those existing buildings that undergo Level 1 alterations, which includes replacement or covering of existing materials, elements, equipment or fixtures using new materials for the same purpose. The purpose of this chapter is to provide detailed requirements and provisions to identify the required improvements in the existing building elements, building spaces and building structural system. This chapter requires only replacement of building components with new components.

  • 706.2 Addition or replacement of roofing or replacement of equipment. This section establishes the requirement that any existing gravity load-carrying structural element for which an alteration causes an increase in design dead, live or snow load, including snow drift effects, of more than 5 percent is to be replaced or altered as needed to carry the gravity loads required by the IBC.

Chapter 8: Alterations—Level 2

The purpose of Chapter 8 is to provide detailed requirements and provisions to identify the required improvements in the existing building elements, building spaces and building structural system when the building’s alteration involves space reconfiguration that could be up to and including 50 percent of the area of the building.

  • 805.2 Existing structural elements carrying gravity loads. This section establishes the requirement that any existing gravity load-carrying structural element for which an alteration causes an increase in design dead, live or snow load, including snow drift effects, of more than 5 percent shall be replaced or altered as needed to carry the gravity loads required by the IBC.

Chapter 11: Additions

Chapter 11 provides the requirements for additions, which correlate to the code requirements for new construction.

  • 1103.1 Additional gravity loads. This section requires that any existing gravity load-carrying structural element for which an addition and its related alterations cause an increase in design dead, live or snow load, including snow drift effects, of more than 5 percent is to be replaced or altered as needed to carry the gravity loads required by the IBC.

Read-Only Version of the IEBC

International Residential Code®

Part II

Chapter 2: Definitions

These definitions provide a common language for designing buildings to resist snow-related hazards and events. They help us understand snow hazard intensity, determine the loads buildings must withstand, and describe the structural systems and connections needed to create a continuous load path. Together, they ensure that buildings are designed with appropriate safety factors, sturdier connections and stronger performance in snow-prone areas.

Part III Building Planning and Construction

Chapter 3: Building Planning

Chapter 3 contains a wide array of building planning requirements that are critical to designing a safe and usable building. This includes but is not limited to general structural design as it relates to snow. Examples of snow-related provisions include:

Section R301 Design Criteria

  • R301.2.3 Snow loads The provisions in this section establish the requirement that ground snow loads are to be determined in accordance with figures in the IRC or in accordance with the IBC. It also specifies that wood-framed construction, cold-formed, steel-framed construction and masonry and concrete construction, and structural insulated panel construction in regions with ground snow loads of 70 pounds per square foot or less, can be constructed based on the tables provided. However, when the ground snow loads exceeds 70 pounds per square foot, the building is to be engineered.
  • R301.6 Roof load The provisions in this section establish the requirement that the roof is to be designed for the live load or the ground snow load, whichever is greater.

Chapter 5: Floors

Chapter 5 provides the requirements for the design and construction of floor systems that will be capable of supporting minimum required design loads. This includes a floor’s ability to support required design loads, including snow loads where applicable. This chapter covers wood floor framing, wood floors on the ground and cold-formed steel floor framing. Examples of snow-related provisions include:

Section R507 Exterior Decks

  • R507.1 Decks. This section establishes the requirement that all wood-framed decks are to be designed for the live load or the ground snow load, whichever is greater.

Chapter 8: Roof-Ceiling Construction

Chapter 8 addresses, among other things, the design and construction of wood framed and cold-formed steel framed roof-ceiling framing systems.

Section R806 Roof Ventilation

  • R806.1 Ventilation required. This section requires that enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters are to have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow.

Chapter 11: Energy Efficiency

The purpose of Chapter 11 is to provide minimum design requirements that will promote efficient utilization of energy in buildings. The requirements are directed toward the design of building envelopes with adequate thermal resistance and low air leakage, and toward the design and selection of mechanical, water heating, electrical and illumination systems that promote effective use of depletable energy resources.

Section N1103 (R403) Systems

  • 1103.9.2 (R403.9.2) Snow melt and ice system controls This section stipulates that snow- and ice-melting systems, supplied through energy service to the building, are to include automatic controls capable of shutting off the system when the pavement temperature is greater than 50°F (10°C) and precipitation is not falling, or an automatic or manual control that will allow shutoff when the outdoor temperature is greater than 40°F (4.4°C).

Chapter 22: Special Piping and Storage Systems

Chapter 22 addresses fuel oil piping and storage related to oil-fired heating appliances. Materials, joining methods, tanks, pumps, valves and installation of such are covered.

  • 2203.5 Vent termination This section establishes the requirement, among others, that the outer ends of vent piping is to terminate sufficiently above the ground to avoid being obstructed by snow and ice.

Chapter 31: Vents

Chapter 31 regulates connection locations, various venting system arrangements and the sizing of piping for vent systems.

Section P3103 Vent Terminals

  • 3103.1.1 Roof extension. This section requires that open vent pipes that extend through a roof are to terminate not less than 6 inches above the roof or 6 inches above the anticipated snow accumulation, whichever is greater.
  • 3103.1.3 Roof extension covered. This section establishes the requirement that where an open vent pipe terminates above a sloped roof and is covered by either a roof-mounted panel or a roof element, the vent pipe is to terminate not less than 2 inches above the roof surface and is to be designed to prevent the adverse effects of snow accumulation and wind on the function of the vent.

Read-Only Version of the IRC

International Building Code®

Chapter 1: Scope and Administration

Chapter 1 establishes the limits of applicability of the code and describes how the code is to be applied and enforced.

  • 1104.1.2 Structural plans, specifications and engineering details This section establishes the requirement that submittal documents include details for each wind region, seismic design category and climate zone for which approval is sought; including design load criteria, including frost depth, live loads, snow loads, wind loads, earthquake design date and other special loads.

Chapter 2: Definitions

These definitions provide a common language for designing buildings to resist snow-related hazards and events. They help us understand hazard intensity, determine the forces buildings must withstand, and describe the structural systems and connections needed to create a continuous load path. Together, they ensure that buildings are designed with appropriate safety factors, sturdier connections, and stronger performance in high-risk areas.

Chapter 9: Fire Protection and Life Safety Systems

Chapter 9 prescribes the minimum requirements for active fire protection equipment systems to perform the functions of detecting a fire, alerting the occupants or fire department of a fire emergency, mass notification, gas detection, controlling smoke and controlling or extinguishing the fire. This chapter parallels and is substantially duplicated in Chapter 9 of the International Fire Code®.

  • 909.4.5 Climate This section establishes the requirement that fire systems are to be designed to consider the effects of low temperatures on systems, property and occupants. For example, air inlets and exhausts are to be located to prevent snow or ice blockage.

Chapter 12: Interior Environment

Chapter 12 provides minimum provisions for the interior / occupied environment. Ventilation, lighting, and space heating are directly regulated in this chapter and in conjunction with the International Mechanical Code® and the International Energy Conservation Code®. Minimum room size, maximum room-to-room sound transmission and classroom acoustics are set for educational occupancies.

  • 1202.2.1 Ventilated attics and rafter spaces This section addresses enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof framing members. It requires that cross ventilation for each separate space be provided by ventilation openings that are protected against the entrance of rain and snow.

Chapter 15 Roof Assemblies And Rooftop Structures

Chapter 15 provides minimum requirements for the design and construction of roof assemblies and rooftop structures to provide weather protection from events such as ice and ice buildup. The criteria address the weather-protective barrier at the roof. The chapter is largely prescriptive in nature and is based on decades of experience with various traditional materials, but it also recognizes newer products.

  • 1507.5.7 Flashing This section requires that roof valley flashing be of corrosion-resistant metal of the same material as the roof covering or comply with the standards found within the chapter. Additionally, there are requirements for areas where the average daily temperature in January is 25°F (-4°C) or less or where there is a possibility of ice forming along the eaves causing a backup of water.
  • 1507.8.1.1 Solid sheathing required This section requires that solid roof deck sheathing be used in areas where the average daily temperature in January is 25°F (-4°C) or less or where there is a possibility of ice forming along the eaves causing a backup of water.

Chapter 16 Structural Design

Chapter 16 establishes minimum design requirements so that the structural components of buildings are proportioned to resist the loads that are likely to be encountered. In addition, this chapter assigns buildings and structures to risk categories that are indicative of their intended use. The loads specified herein along with the required load combinations have been established through research and service performance of buildings and structures. The application of these loads and adherence to the serviceability criteria enhance the protection of life and property.

  • 1603.1.3 Roof snow load data This section states that the ground snow load is to be indicated on the plans when the ground snow load exceeds 15 pounds per square foot. Additional information that is to be provided, regardless of whether snow loads govern the design of the roof includes: Flat-roof snow load, Snow exposure factor, Risk category, Thermal factor, Slope factor(s), Drift surcharge load(s), Width of snow drift(s), and Winter wind parameter for snow drift.
  • 1608.1 General This section directs the designer to Chapter 7 of ASCE/SEI 7 when computing design snow loads, but the design roof load are not to be less than those established in Section 1607 of the IBC.
  • 1608.2 Ground snow loads This section directs the designer to Chapter 7 of ASCE/SEI 7 when computing ground snow loads or various Figures and Tables found in the IBC.

Chapter 21: Masonry

Chapter 21 establishes minimum requirements for masonry construction and its provisions provide a framework for applying applicable standards to the design and construction of masonry structures.

  • 2109.2.4.8.9.3 Weather-exposed locations This section addresses clay plaster exposed to water from direct or wind-driven rain or snow. The provisions within this section require the clay plaster to be finished with an approved erosion-resistant finish and it is not permitted to be used on weather-exposed parapets.

Chapter 31: Special Construction

Chapter 31 provides regulations for unique buildings and building elements. Those include buildings such as membrane structures, greenhouses and relocatable buildings. Special elements include pedestrian walkways and tunnels, awnings, canopies and marquees, vehicular gates, solar energy systems, public use restrooms in flood hazard areas, and intermodal shipping containers.

  • 3102.7 Engineering design The provisions in this section require that the structure be designed and constructed to sustain dead loads; loads due to tension or inflation; live loads including wind, snow or flood and seismic loads.
  • Section 3103.6.1.1 Snow loads The provisions in this section require that snow loads on public-occupancy temporary structures are to be designed for and may be permitted to be modified in accordance with the ground snow load reduction factors.

Read-Only Version of the IBC

Snow Resources

Preparedness

Emergency Planning

Individuals and households can use Ready.gov resources to make emergency plans, prepare for possible power outages, receive alerts and take steps to stay safe before snow and winter storm events.

Storm Preparedness

Learn how to stay safe before, during and after a winter storm. For more information on winter alerts, science and hazards, snow coverage maps and information describing the different types of winter storms.

Training for Officials

When Disaster Strikes Institute’s Disaster Planning for the Building Department, a course that helps building and fire code officials understand roles, responsibilities and readiness strategies before snow-related disasters.

Response

Stay Safe

During and after a snow event, individuals should follow local emergency alerts, avoid unsafe travel when conditions are hazardous, stay away from damaged structures and report life-safety concerns to local authorities.

Training for Officials

ICC's When Disaster Strikes Institute’s Initial and Preliminary Damage Assessment and Building Safety Evaluator training courses train how to safely assess post event structures and determine habitability.

Recovery

International Codes®

Clear documentation and consistent definitions in the I‑Codes can support faster recovery and more consistent enforcement after snow and winter storm events.

Pairing Mitigation with Local Recovery

Recovery is an opportunity to reduce future risk. After a snow event, local leaders, recovery committees and planning teams can use hazard mitigation plans, damage assessments and community input to guide rebuilding decisions that make homes, businesses, infrastructure and public facilities more resilient.

Use hazard mitigation plans as roadmaps

Use state and local hazard mitigation plans to guide where recovery projects should be located, how they should be designed and which funding opportunities may support them.

Conduct post‑event damage & risk assessments

Document damage, identify recurring problem areas and use the findings to support mitigation-focused rebuilding.

Embed mitigation in all recovery discussions

Include mitigation options in town halls, planning meetings and community workshops so risk reduction is considered early and consistently.

Prioritize multi‑hazard strategies

Consider other local hazards, such as flooding, wildfire and tornadoes, and look for recovery projects that reduce exposure to more than one hazard.

Leverage recovery funding for mitigation

Explore federal, state and local funding programs that allow or encourage mitigation as part of repair and reconstruction.

Rebuild with resilience

Encourage materials, installation methods and infrastructure designs that account for snow loads, ice buildup, roof drainage and long-term winter weather risk.

Engage the community

Involve residents, businesses and local organizations so mitigation measures reflect local needs and support long-term resilience.