International Wildland Urban Interface Code®
Chapter 1 – Scope and Administration
Chapter 1 establishes the administrative framework for applying the IWUIC when adopted by a state or jurisdiction. It addresses scope, administration and how the adoption - such as whether appendices are enforceable - is activated through an adopted ordinance and the authority of the code official.
Key IWUIC references: Chapter 1, including Section 101.2.1 (Appendices).
Key terms (defined in Chapter 2): Scope, Applicability, Code official/authority, Permits, Construction documents, Approved agency, Alternative materials or methods, Appeals.
Chapter 2 – Definitions
Chapter 2 provides definitions used throughout the IWUIC. These definitions support consistent interpretation and enforcement of WUI area designations, defensible space, ignition-resistant construction and fire protection concepts across the code.
Key IWUIC references: Chapter 2, including Sections 201 (General) and 202 (Definitions).
Key terms (defined in Chapter 2): Wildland-urban interface area, Wildfire, Defensible space, Fire hazard severity, Ignition-resistant construction, Fuel (light/medium/heavy).
Chapter 3 — Wildland-Urban Interface Areas
Chapter 3 explains how WUI areas are identified so a community can determine where IWUIC requirements apply. It supports both mapped and procedure-based designation approaches and provides a basis for documenting designations and updates over time.
Key IWUIC references: Sections 301 (General) and 302 (WUI area designations), including Sections 302.2 (Mapping) and 302.3 (Review of WUI areas).
Key terms (defined in Chapter 2): Wildland-urban interface area, Wildland, Mapping of wildland-urban interface area, Wildland-urban interface area designations, Findings of fact, Fire hazard severity, Fire hazard severity form.
Chapter 4 — Wildland-Urban Interface Area Requirements
Chapter 4 addresses site and development requirements for projects in designated WUI areas. The provisions focus on enabling safe and effective fire service operations by addressing access and related infrastructure considerations which are often coordinated with local fire department standards.
Key IWUIC references: Sections 401 (General) through 405 (as applicable), including Sections 402.1.1 (Access), 403.2 (Driveways), and 403.3 (Fire apparatus access road).
Key terms (defined in Chapter 2): Access, Driveways, Fire apparatus access road, Address markers, Subdivision, Service utilities, Water supply, Fire flow calculation area.
Chapter 5 — Special Building Construction Regulations
Chapter 5 focuses on how buildings can better resist wildfire exposures. It provides ignition-resistant construction concepts and requirements based on identified severity level intended to reduce susceptibility to ignition, with emphasis on common ignition pathways such as embers and exposure to heat and flame.
Key IWUIC references: Sections 501 (Scope) and 503 (Ignition-Resistant Construction and Material).
Key terms (defined in Chapter 2): Ignition-resistant construction (Classes 1–3), Ignition-resistant building material, Noncombustible, Roof assembly, Roof covering, Noncombustible roof covering, Fire-retardant-treated lumber or wood, Multilayered glazed panels, Flame spread index.
Chapter 6 — Fire Protection Requirements
Chapter 6 addresses wildfire-related fire protection measures that complement site and construction provisions. It includes topics such as automatic suppression provisions (where applicable), fuel modification concepts, defensible space maintenance, and fire protection considerations for hazards and equipment commonly present in WUI settings.
Key IWUIC references:Selected sections include 602.1 (Automatic sprinkler systems), 603.2 (Fuel modification), 604 (Defensible space/maintenance), and 606 (Liquefied petroleum gas installations).
Key terms (defined in Chapter 2): Automatic sprinkler systems, Defensible space, Maintenance of defensible space, Fuel modification, Fuel modification distance, Vegetation control, Vegetation management plan, LP-gas installations, Storage of firewood and combustible materials, Spark arrestors.
Chapter 7 — Referenced Standards
Chapter 7 lists the external standards that are referenced by the IWUIC. When a state or jurisdiction adopts the IWUIC, these referenced standards become part of the compliance framework for IWUIC provisions that rely on test methods, product standards and installation criteria.
Key IWUIC references: Chapter 7 (Referenced Standards).
Key terms (defined in Chapter 2): Referenced standards, Approved, Approved agency, Listed (as applicable), Inspection and enforcement.
Appendices (Optional—Apply Only When Adopted)
Appendices provide supplemental tools and provisions that a state or jurisdiction may choose to adopt. Their applicability depends on adoption language (see Section 101.2.1).
- Appendix A — General Requirements
Appendix A provides supplemental fire protection measures that support wildfire risk reduction, including vegetation control, ignition source controls, storage practices and protection of water supply equipment. It can be adopted to supplement Chapter 6 where a jurisdiction wants additional operational and preventive measures.
Key IWUIC references: Appendix A, including Sections A101 (General) and A102 (Vegetation control).
Key terms (defined in Chapter 2): Vegetation control, Ignition source control, Control of storage, Hazardous materials, Protection of pumps and water storage facilities, Temporary structures and uses.
- Appendix B — Vegetation Management Plan
Appendix B provides a framework for preparing a vegetation management plan when required. It helps document the actions, methods and schedules that will be used to manage fuels and defensible space in a way that is clear, repeatable and maintainable.
Key IWUIC references: Appendix B, including Sections B101.1 (Scope) and B101.2 (Plan content).
>Key terms (defined in Chapter 2): Vegetation management plan, Defensible space, Fuel mosaic, Fuel-loading, Fire-resistive vegetation.
- Appendix C — Fire Hazard Severity Form
Appendix C provides a form-based tool that jurisdictions may use to document fire hazard severity considerations. This can support consistent determination and communication of wildfire exposure and severity classifications in local implementation.
Key IWUIC references: Appendix C, including Section C101.1 and Table C101.1 (as applicable).
Key terms (defined in Chapter 2): Fire hazard severity, Fire hazard severity form, Critical fire weather, Slope.
- Appendix D — Fire Danger Rating System
Appendix D provides a structured fire danger rating approach that can support operational decisions during periods of heightened wildfire risk. When adopted, it can help guide restrictions or heightened precautions in WUI areas during critical fire weather.
Key IWUIC references: Appendix D (Fire Danger Rating System).
Key terms (defined in Chapter 2): Fire danger rating system, Fire danger rating, Critical fire weather.
- Appendix E — Findings of Fact
Appendix E provides a findings-of-fact framework that can support documentation for WUI designations and other determinations where a documented basis is needed. It helps create transparent, repeatable decision-making processes.
Key IWUIC references: Appendix E (Findings of Fact).
Key terms (defined in Chapter 2): Findings of fact, Mapping, Wildland-urban interface area designations.
- Appendix F — Characteristics of Fire-Resistive Vegetation
Appendix F provides information on characteristics associated with fire-resistive vegetation. It can be used as guidance when evaluating landscaping and vegetation choices that contribute to reduced ignition potential near structures.
Key IWUIC references: Appendix F (Characteristics of Fire-Resistive Vegetation.
Key terms (defined in Chapter 2): Fire-resistive vegetation, Trees, Tree crown.
- Appendix G — Self-Defense Mechanism
Appendix G provides alternative concepts that jurisdictions may use as an implementation tool for communities and property owners to help protect exposed structures. Where used, it can help organize protective actions and increase options for structure preparedness.
Key IWUIC references: Appendix G (Self-Defense Mechanism).
Key terms (defined in Chapter 2): Self-defense mechanism, Emergency access, Fire weather.
- Appendix H — IWUIC Flowchart
Appendix H provides a flowchart-style navigation aid intended to help users understand the application of the IWUIC. It may support consistent application and communication of requirements based on fire hazard severity.
Key IWUIC references: Appendix H (International Wildland-Urban Interface Code Flowchart).
Key terms (defined in Chapter 2): Flowchart, Applicability, Compliance alternatives.
Read-Only Version of the IWUIC